XR500 Series Canadian Programming Guide 
Digital Monitoring Products
23
remoTe oPTionS
7.4.3        
PC Modem 
YES allows the panel to answer the telco link and connect with Remote Link through
the PC Modem at 2400 baud. NO disables PC Modem communication.
7.4.4        
Manufacturer Authorization
Select YES to allow DMP Technical Support technicians to access the panel during 
system service or troubleshooting.  This authorization automatically expires within 
one hour.  
DMP remote service is provided on a read only basis:  DMP technicians can look 
at the system programming and make suggestions only. Alterations can only be 
accomplished by installing company service personnel.
7.5 
 
Allow Network Remote
This option displays only if the panel has network capability.  YES allows remote 
programming over the network.  Changing this prompt does not change any other 
network programming prompts.  Default is YES.
7.5.1 
NETWORK PROG
 Network Programming Port
PORT:   
  2001
 
Enter the programming port number. The programming port identifies the port used
to communicate messages from the panel.  The default Programming Port setting is 
2001. 
 
7.5.2   
Encrypt Network Remote
YES encrypts data sent over network. Default is NO.
7.6 
 
Allow Cellular Remote
YES allows remote programming using cellular connection.  Default is YES. 
7.6.1   
First GPRS APN
Enter the first APN (Access Point Name). This allows an access point for cellular
communication and is used to connect to a DNS network. The APN may contain two 
lines of 16 characters to equal 32 characters. Default is set to SECURECOM400.
 
 
Second GPRS APN
Enter the second APN (Access Point Name). This works as a backup in case the first
APN fails. The APN may contain two lines of 16 characters to equal 32 character
Default is set to SECURECOM400.
7.6.2   
Encrypt Cellular Remote
YES encrypts data sent over a cellular connection. Default is NO.
7.7 
 
Allow RS-232 Remote
YES allows remote programming over the on-board RS-232 port. Default is YES.
7.8 
 
Entré Connection
This option displays only if the panel has network capability.  Select NET to allow 
a dedicated network connection with Entré. Options are NONE or NET. Default is
NONE.
7.8.1   
Entré Incoming TCP Port
 
This option displays only if NET is chosen for the Entré connection. Enter the
programming port number for the incoming Entré connection. The programming port
identifies the port used to communicate messages to and from the Entré software.
This port cannot be the same port as programmed in Network Programming Port.  
The default Programming Port setting is 2011.  
7.8.2 
 Entré IP Address
 
 
This option displays only if NET is chosen for the Entré connection. Enter the Entré
IP address where the panel sends network messages. The Entré IP Address must be
 
 
unique and cannot be duplicated on the network.  Enter all 12 digits and leave out  
the periods. For example, enter IP address 192.168.0.250 as 192168000250. The
 
 
periods  display automatically.  Default is 0.0.0.0
7.8.3   
Entré Outbound TCP Port
 
This option displays only if NET is chosen for the Entré connection. Enter the
programming port number for the outbound Entré connection. The programming port
identifies the port used to communicate messages to the Entré software. Default is
2001.  
SECURECOM400
-
FIRST GPRS APN:
SECURECOM400
-
SECOND GPRS APN:
ENCRYPT  NETWORK    
REMOTE? 
NO  YES
ALLOW  CELL    
REMOTE? 
NO  YES
ENCRYPT  CELL    
REMOTE? 
NO  YES
ALLOW  232    
REMOTE? 
NO  YES
ENTRE
CONNECTION:   NONE
ENTRE INCOMING
TCP PORT:         2011
000.000.000.000
ENTRE IP 
 
ENTRE OUTBOUND
TCP PORT:         2001
AUTH?    
NO  YES
ALLOW  NETWORK    
REMOTE? 
NO  YES
PC MODEM  NO  YES
MANUFACTURER