DMP Electronics XR500 사용자 설명서

다운로드
페이지 84
Digital Monitoring Products 
XR500 Series Canadian Programming Guide
50
zone informaTion
19.7 
 
ARM/DIS AREAS
 Arming Zone Area Assignment
In an Area or Home/Sleep/Away with Guest system, if the zone has been
programmed as an Arming Type (AR), enter the areas that the zone controls.
When the zone changes from normal to shorted, the programmed areas toggle between
the armed or disarmed condition using the Style programming below. When restored to
normal, no action occurs. When the zone is opened from a normal (disarmed) state, a
trouble is reported. When opened from a shorted (armed) state, an alarm is reported
and the zone is disabled until you disarm the area(s) from either a keypad or Remote
Link™ computer.
To visually indicate the armed state of the area(s), you can assign an Armed Output
to individual areas and use remote LEDs at the keyswitch. The LED turns on or off to
indicate to the user the armed state of the area(s).
 
ARM AREAS:   PERIM
In an All/Perimeter or Home/Sleep/Away system, this option specifies the areas to
be armed by the Arming Type zone. For All/Perimeter systems, choose PERIM or ALL,
for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
 
PERIM   
  ALL
Perimeter/All - Specify whether the arming zone arms just the Perimeter (PERIM) or
the Perimeter and Interior areas (ALL) for All/Perimeter systems. When disarming,
all areas are disarmed.
 
HOME SLEEP  AWAY
Home/Sleep/Away - Specify whether the arming zone arms the Perimeter (HOME),
the Perimeter and Interior (SLEEP), or all three areas (AWAY). When disarming, all
areas are disarmed.
Arming Zone Operation
If any bad zones are present when the Arming zone is shorted, the LED delays
lighting for 5 seconds. If during the 5-second delay the Arming zone is shorted
again no arming takes place.  If 5 seconds expire without the zone shorting again 
or restoring to normal, the areas arm and bad zones are force armed.  To allow bad 
zones to be force armed, the Any Bypass option must be set to YES.  If Any Bypass 
option is set to NO, arming does not occur. See the Area Information - Any Bypass
section.  A priority zone cannot be force armed.
19.8 
STYLE:
 Style
This option specifies the style for the arming/disarming operation. The default style
is TGL (toggle). Press any Select key to display the STYLE options. To view more
style options press the COMMAND key.
TGL  ARM  DIS   STEP
 
TGL (Toggle) - When the zone changes from normal to shorted, the programmed
areas toggle between the armed or disarmed condition. When restored to normal,
no action occurs. When the zone opens from a normal (disarmed) state, a trouble is
reported. When opened from a shorted (armed) state, an alarm is reported and the
zone is disabled until you disarm the area(s) from either a keypad or Remote Link.
ARM - When the zone is shorted, the programmed areas are armed. When restored to
normal, no action occurs. When the zone is opened from a normal (disarmed) state, a
trouble is reported. When opened from a shorted (armed) state, an alarm is reported.
DIS (Disarm) - When programmed, a short disarms the programmed areas. When
restored to normal, no action occurs. When the zone is opened from a normal
(disarmed) state, a trouble is reported.
STEP - A short arms the areas and beeps the keypads once.  A normal condition 
causes no action.  An open condition disarms the programmed areas and beep the  
keypads for one second.
Note: This arming style is designed for wireless arming pendants. When using an
arming/disarming keyswitch locate the keyswitch within the protected area.
MNT
 
MNT (Maintain) - When the zone is shorted, the programmed areas are armed.
When restored to normal, the programmed areas are disarmed and any alarm bells
are silenced. When the zone is opened from a normal (disarmed) state, a trouble
is reported. If opened from a shorted (armed) state, an alarm is reported and the
zone is disabled until you disarm the area(s) from either a keypad or Remote Link.