CHAP. 5  Set Up
Set type of alarm sensors connected to DVR unit.
N.O represents Normal Open type and N.C Normal Close type.
5) ALARM SETUP
4) INTERVAL SETUP
Set the switching time interval for SEQ or PIP
function.(1 sec. ~ 99 sec.)
FULL SCREEN : set the sequencing switch time interval 
in live full screen.
PIP SCREEN : set the sequencing switch time interval 
of PIP window.
EVENT UPDATE TIME : Set the minimum time interval of event to be listed in EVENT LIST. 
If EVENT UPDATE TIME is set at 20 sec, only following event happened 
20 sec or more than 20 sec later previous event shall be listed in EVENT LIST.
1) ALARM INPUT : Select type of alarm sensor connected to DVR unit (N.O or N.C).
Use direction button and [-] [+] button to set.
DISABLE represents not to use alarm sensor connected to DVR.
2) DURATION : Set the duration of alarm when an ALARM is activated. (0 sec. ~ 300 sec.)
INTERVAL SETUP
SWICHING INTERVAL
FULL SCREEN
PIP  SCREEN
:  01 SEC
:  01 SEC
EVENT RECORD
EVENT UPDATE TIME
:  01 SEC
SELECT ▲▼◀▶, CHANGE VALUE :  + -
N.O ................................ NORMAL OPEN
N.C ................................ NORMAL CLOSE
....................................... DISABLE
CH1
N.O
005
SELECT : ▲▼, CHANGE VALUE : + -
CHANNEL
ALARM INPUT
DURATION
ALARM SETUP