5. The pilot pressure should be adjusted as follows:
•
The current flow between the pilot hood and the
flame sensor, when measured with a microamp
meter or multimeter, holds constant at a minimum
of 2.0 µA.  See Figure 7.
•
The pilot pressure as shown on the manometer is in
the range of 3-1/2” - 4” W.C. (8.7-10.0 mbar).
Adjust the pilot pressure as necessary by turning the
pilot adjustment screw on the combination gas control
valve.  Turning the screw clockwise decreases the pilot
pressure.  Turning the screw counter-clockwise increases
the pressure.
Some valves may have a burr in the pilot adjustment
portal.  If you have fully tightened the adjustment screw,
and the manometer still does not register a change in
pressure, continue to tighten the screw to break through
the burr.  Back the screw out until its top is flush with the
top of its hole, then tighten the screw again as necessary
to  adjust  the  pressure.    Repeat  this  procedure  as
necessary to properly adjust the pilot pressure.
If the pilot pressure cannot be properly adjusted, switch
the  oven  off  and  allow  it  to  cool;  then,  replace  the
combination gas control valve.  Repeat Section VII (Gas
Leak Test) before attempting to adjust the pilot pressure
again.
7. After the pilot pressure has been properly adjusted,
replace the cap screw.
8. Reset the oven’s set point temperature to the customer’s
original settings.  Leave the oven in operation to allow
the manifold pressure to be checked in the next Section
of these instructions.
X. MANIFOLD PRESSURE ADJUSTMENT
1. Remove the regulator cap screw from the combination
gas control valve.
2. Using a manometer, check the pressure at the manifold
pressure tap, as shown in Figure 6.  A manifold pressure
of 3-1/2” W.C. (8.7mbar) is recommended for natural
gas operation.
3. Adjust  the  pressure  as  necessary  by  turning  the
adjustment screw on the combination gas control valve.
Turning the screw clockwise decreases the pressure.
Turning  the  screw  counter-clockwise  increases  the
pressure.
If the manifold pressure cannot be properly adjusted,
switch the oven off and allow it to cool; then, replace the
combination gas control valve.  Repeat Section VII (Gas
Leak Test) before attempting to adjust the manifold
pressure again.
4. After the manifold pressure has been properly adjusted,
replace the cap screw.  Record the final value on the Gas
Conversion Label, as shown in Figure 8.
5. Switch the oven off, and allow it to cool.
XI. MARKING AND LABELING
1. Print the word “NATURAL” in the space provided on the
Gas Control Conversion Tag, P/N 22501-0007.  See
Figure 8.  Fasten the tag onto the gas piping next to the
combination gas control valve.
2. Locate the round “LPG” label (red) on the burner or
burner  motor.    Attach  the  kit-supplied  yellow/green
“NAT” label, P/N 22500-0064, on top of the “LPG” label.
The new label should completely cover the “LPG” label.
See Figure 8.
3. Complete the information on the Gas Conversion Label
as shown in Figure 8.
4. Attach the Gas Conversion Label in plain view on the
outside of the oven, as close as possilble to the oven’s
serial plate.
Figure 8
Attach  to  gas
piping  next  to
combination
gas  valve
Attach  on  top  of
existing  “LPG”
label  (on  burner  or
burner  motor)
Date of
conversion
Measured value
from Section X
See chart on
Page 1
Stated on the oven’s
serial plate
Part no. of this
Kit - see chart
on Page 1
Name of
technician
Attach  completed  label  in  plain
view  near  serial  plate
New label completely
covers “LPG” label
Figure 7
Pilot hood ( - )
Flame sensor ( + )
SECTION 3 - SERVICING COMPONENTS
Appendix - Instructions for All Gas Conversion Kits
for Ovens with Wayne Burner, Propane to Natural Gas, 8/00