8
2.3 ALARM In/Out 
ALARM IN
ALARM OUT
RECORD IN
GROUND
DISK FULL
ALARM RESET
NO CONNECTION
NO CONNECTION
SWITCH OUT
1
2
3
4
5
6
7
8
9
 
 
 
THIS FIGURE IS FROM THE REAR VIEW 
1. 
GROUND: Ground Contact. 
2. 
A LARM OUT (OUTPUT): This is an alarm output trigger. Connect this to external devices such 
as buzzers or lights. (
5V
0V(Active)
) 
3. 
DISK FULL (O UTPUT):  This is a disk full output trigger.  Connect this to external devices such 
as buzzers or lights. (
5V
0V(Active)
) 
4. 
A LARM   RESET (INPUT):  This pin connects to an alarm-clear device for clearing an alarm. 
(
5V
0V(Active)
) 
5. 
REC ORD (INPUT):  This pin connects to a record trigger device for  starting a record. 
(
5V
0V(Active)
) 
6. 
SWITCH OUT  (OUTPUT):  This pin sends out timing signals (falling / negative) to a multiplexer 
and connects to a multiplexer’s trigger terminal so the multiplexer can switch to use the same 
recording speed as the DVR.  (Refer to Section 4.1.1 for multiplexer configuration.) 
7. 
NO CONNECTION 
8. 
NO CONNECTION 
9. 
A LARM IN (INPUT):  This is an alarm input which can be programmed in the menu system to 
Normally Open or Normally Closed. (
5V
0V(Active)
)