Maxtor NVR-2028 사용자 설명서

다운로드
페이지 91
 
87
APPENDIX 2. –RS-232 Protocol 
 
1. Setup 
 
1.1  Use a Null Modem cable (the standard RS-232 9 Pin Cable with Pin 2 and Pin 3 
exchanged, see pin configuration chart below for details) to connect the COM 1 on the rear 
panel of the NVR-2028 to a PC. 
 
NVR
 
 
1.2 Set the RS-232 option to ON in the COMMUNICATION page of the setup menu. 
 
1.3 Set the PC communication parameters: 9600 bps, No Parity, 8 Data Bits, 1 Stop Bit. 
 
2. Communication Protocol 
 
 
2.1 General Command Format 
<Lead Code = 0x41>, < Dest ID >, < Src ID >, <Main category >, <Second category >, 
{<Number of parameters>,<Parameter 1>, <Parameter 2> ..,} <End Code= 0x4f> 
 
 
 
   
     Lead Code  = 0x41 
Dest ID     = 0x01 
Src ID     = 0x20 
   
     Main Category  = 0x01   Keys and Signals 
 
 
           
   
= 0x02   Command 
               Second Category  = 0x01 Handshake 
   
 
                
= 0x02 Request Time/Set Time 
   
 
 
      
 
= 0x06 Request System State 
= 0x0b Time Search 
   
     End Code= 0x4f 
 
         The different command types and their corresponding parameters are as follows: 
2.2 Keys and signals 
PC Send: <0x41>, <0x01>, <0x20>, <0x01>, <Key Value(Low byte)>,   
<Key Value(High byte)>,<0x4f>