Parker Hannifin mx80l standard grade 사용자 설명서
MX80L Series Product Manual
Chapter 2 – MX80L Series Table Specifications
Parker Hannifin Corporation
21
MX80L Series Technical Data
Force/Speed Charts
The Force/Speed Charts for the MX80L are shown for each available travel. In the maximum allowable
travel range the motor force is the same for 80 and 48 VDC bus voltage. See Electrical Specifications for
motor parameters. Performance based on table mounted to 200mmx150mmx20mm Aluminum plate.
Curves shown include friction and viscous damping values of table
travel range the motor force is the same for 80 and 48 VDC bus voltage. See Electrical Specifications for
motor parameters. Performance based on table mounted to 200mmx150mmx20mm Aluminum plate.
Curves shown include friction and viscous damping values of table
. Peak speed is limited by travel
length for 25mm [T01] and 50mm [T02] travel lengths.
[D11] 4-pole Motor Force-Speed Curve
([
T01] 25 mm travel)
Rated Force Speed Curve
( 80 & 48 VDC)
Continuous
Peak
0
2
4
6
8
10
12
14
0
200
400
600
800
1000
1200
Speed mm/s
Fo
rc
e N
[D11] 4-pole Motor Force-Speed Curve
([T02] 50 mm travel)
Rated Force Speed Curve
(80 & 48VDC)
Continuous
Peak
0
2
4
6
8
10
12
14
0
300
600
900
1200
1500
Speed mm/s
Fo
rc
e N
Daedal Division
Irwin, Pennsylvania
Irwin, Pennsylvania