Parker Hannifin mx80l standard grade 사용자 설명서

다운로드
페이지 40
MX80L Series Product Manual  
 
Chapter 5 - Connecting the ViX Amplifier 
 
Parker Hannifin Corporation
37 
 
Chapter 5 - Connecting to the ViX Amplifier  
 
The MX80L is designed to be plug and run compatible with the Parker ViX drive.  The cables on 
the MX80L are labeled to match the labels on the ViX for ease of use and quick installation.  When 
purchased as part of the part number, the ViX will have the motor parameters already downloaded. 
                      
  
X1 – MOTOR LEADS 
WIRE COLOR 
DRIVE 
RED U 
WHITE V 
BLACK W 
GREEN GND 
X2 – FEEDBACK-HALL CONNECTOR 
PIN FUNCTION 
WIRE 
COLOR 
1 Encoder 
Z+ 
ORANGE 
2 Encoder 
Z- 
BROWN 
3 GND 
BLACK 
5 +5V 
RED 
6 Temperature- YELLOW/BLACK 
7 Encoder 
A+ 
WHITE 
8 Encoder 
A- 
YELLOW 
9 Hall#1  WHITE/BROWN 
10 Temperature+  YELLOW/RED 
11 Encoder 
B- 
BLUE 
12 Encoder 
B+ 
GREEN 
13 Hall#2  WHITE/ORANGE 
14 Hall#3  WHITE/VIOLET 
X5 – LIMITS CONNECTOR* 
PIN FUNCTION WIRE 
COLOR 
1 GND  BLACK 
+ End of travel 
ORANGE 
- End of travel 
BLUE 
8 Home  GREEN 
* For Drive Only versions of the ViX, the limits need to 
be connected to the motion controller NOT the drive. 
 
 
 
 
Limits use Inputs 
 
The ViX drive has 5 digital inputs.  When using with MX80L, the EOT Limits and Home use 3 of the 5 inputs.  
A VM15-PF screw terminal breakout board may be purchased to allow access to the remaining 2 inputs and all 
of the outputs.  
 
 
 
 
 
 
Daedal Division 
Irwin, Pennsylvania