Chapter 4  Using Your Tape Drive
LED Indicators
DLT-V4 Product Manual
48
during POST, the 
Ready
 LED flashes until the tape drive executes a mid-
tape load, which can take several minutes. As POST completes, the tape 
drive makes a faint buzzing noise for several seconds. The noise 
associated with this activity is normal for this technology and does not 
indicate a problem with the tape drive.
Normal Operation — 
Ready LED Indicator 
Activity
4
During normal operation, the 
Ready
 LED displays one of the three 
following states. The 
Ready
 LED acts independently of the other LEDs.
Table 13   Ready LED Indicator 
Activity
Normal Operation — Fault / 
Clean / Media LEDs 
Indicator Activity
4
The 
Fault
Clean
, and 
Media
 LEDs work together to display the status of 
the tape drive.
Table 14   Fault / Clean / Media 
LEDs Indicator Activity
State
Description
Off
Indicates that there is no power to the tape drive.
On
Indicates that power is on, no data cartridge is 
loaded, or a loaded data cartridge is idle with no 
tape motion.
Blinking
A data cartridge is in the process of loading, or 
there is tape motion on a loaded data cartridge. 
Tape motion includes reading, writing, locating, 
rewinding, calibrating, and so on.
Fault
Clean
Media
Description
Unsupported format, unsupported 
data cartridge type, or damaged data 
cartridge
A DLT1 (DLT VS 80) formatted 
DLTtape IV data cartridge is loaded. 
Represents a read-only or VS160 
formatted cartridge.
Calibration error or permanent write/
read error, cleaning suggested