3.5.2 OVER- CURRENT PROTECTION 
There shall be protection from an output over-current event. The PSU may 
shutdown form such an event and require power-on restart.   
The overload currents should be ramped at a minimum rate of   
10 A/s starting from full load. 
Over-current test values:   
Output Voltage 
3.3V 
5V 
12V 
Protecting trigger condition  < 60A 
< 45A 
< 70A 
3.5.3 Short-Circuit Protection   
An O/P short circuit is defined as any O/P impedance of less then 0.1 ohms. 
The power supply shall shutdown and latch off for shorting +3.3V, +5V or 
+12V rail to return or any other rail. and +5VSB shall not cause any damage 
to the power supply. The power supply shall either shutdown and latch off or 
fold back for shorting negative rail. +5VSB must be capable of being shorted 
indefinitely, but when the short is removed, the power supply shall recover 
automatically or by cycling PS_ON#. The power supply shall be capable 
withstanding a continuous short-circuit to the O/P without damage or 
overstress to the unit (for example to components, PCB traces, connectors) 
under the I/P conditions specified.   
  3.6  OUTPUT RISETIME 
The cold-start enable main output voltage rise-time of all outputs shall be 
measured with maximum load on all outputs. (with 
COND.9)
Rise time:  +3.3V
20mS (maximum) 
(10-90%)
+5V
20mS (maximum) 
                    
+12 V   20mS (maximum) 
                      
-12 V    20mS (maximum) 
The test condition: 115Vac/60Hz 
3.7  OUTPUT OVERSHOOT/UNDERSHOOT   
No output voltage shall overshoot / undershoot or generate spikes at 
turn-on or turn-off, during momentary power loss, output short, or realistic 
input voltage or output load changes, Overshoot/undershoot is defined as 
any output that exceeds the voltage tolerance plus or minus an additional 5%. 
All outputs shall be measured with minimum load (
COND.3
)
Overshoot 
Undershoot 
+3.3V 
3.63V 
2.97V 
  +5V 
5.5V 
4.5V 
  +12V 
13.2V 
10.8V 
-12V 
-13.8V 
-10.2V 
+5VSB 
5.5V 
4.5V