Juniper EX4300-48P 데이터 시트

다운로드
페이지 12
6
EX4300 Specifications
Physical Specifications
Backplane
•  320 Gbps Virtual Chassis interconnect to combine up to 10 units 
as a single logical device 
Uplink Module Options
•  Dual-mode 4-port 10GbE SFP+/4-port GbE SFP module with 
pluggable SFP+/SFP optics
Power Options
•  Power supplies: Autosensing; 100-120 V/200-240 V; AC 350 w 
AFO, 350 w AFI, 715 w AFO, and 1,100 w AFO dual load-sharing 
hot-swappable internal redundant power supplies
•  Maximum current inrush: 50 amps
•  DC power supply: 550 w DC AFO and 550 w DC AFI; input voltage 
range 36-72 V; dual input feed, dual load-sharing hot-swappable 
internal redundant power supplies
•  Minimum number of PSUs required for fully loaded chassis: 1 per 
switch
Dimensions (W x H x D)
•  17.41 x 1.72 x 16.43 in (44.21 x 4.32 x 41.73 cm)
•  Desktop installation width noted above, rack-mount width is  
17.5 in (44.5 cm) 
•  Height: 1 rack unit (1 U)
System Weight
•  EX4300 switch (no power supply or fan module): 13 lb (5.9 kg)
•  EX4300 switch (with single power supply and two fan modules): 
16.1 lb (7.3 kg)
•  350 w AC power supply: 2.4 lb (1.1 kg)
•  715 w AC power supply: 2.4 lb (1.1 kg)
•  1100 w AC power supply: 2.4 lb (1.1 kg)
•  550 w DC power supply: 2.4 lb (1.1 kg)
•  SFP+ uplink module: 0.44 lb (0.2 kg)
•  Fan module: 0.33 lb (0.15 kg)
Environmental Ranges
•  Operating temperature: 32° to 113° F (0° to 45° C)
•  Storage temperature: -40° to 158° F (-40° to 70° C)
•  Operating altitude: up to 10,000 ft (3,049 m) 
•  Non-operating altitude: up to 16,000 ft (4,877 m)
•  Relative humidity operating: 10% to 85% (noncondensing) 
•  Relative humidity non-operating: 0% to 95% (noncondensing)
Cooling
•  Field-replaceable fans: 2
•  Switch remains operational even if one fan fails
•  Airflow: PSU-7.5 CFM, fan-22 CFM
•  Total maximum airflow throughput with two power supplies:  
59 CFM
Hardware Specifications
Switching Engine Model
•  Store and forward
Memory
•  DRAM: 2 GB with Error Correcting Code (ECC)
•  Flash: 2 GB
CPU 
•  1.5 GHz Dual-Core PowerPC CPU
GbE Port Density per System
•  24P/24T: 28 (24 host ports + four-port 1/10GbE uplink module)
•  48P/48T: 52 (48 host ports + four-port 1/10GbE uplink module)
•  10GbE port density per system (all models): 4 (uplink module) 
•  40GbE port density per system (all models): 4
Supported Optics
•  GbE SFP optic/connector type: LC SFP fiber supporting SX 
(multimode), LX (single-mode) 
•  10GbE SFP+ optic/connector type: 10GbE SFP+ LC connector, SR 
(multimode), USR (multimode), LR (single-mode), ER (single-
mode), LRM (multimode), and DAC (direct-attach copper)
•  40 GbE QSFP+ optic/connector type: 40GbE QSFP+ LC connector 
type, SR (multimode), DAC (direct-attach copper)
Physical Layer
•  Time Domain Reflectometry (TDR) for detecting cable breaks and 
shorts: 24P/24T and 48P/48T only
•  Auto medium-dependent interface/medium-dependent interface 
crossover (MDI/MDIX) support: 24P/24T and 48P/48T only (all 
ports)
•  Port speed downshift/setting maximum advertised speed on 
10/100/1000BASE-T ports: 24P/24T and 48P/48T only, on all 
ports
•  Digital optical monitoring for optical ports
Packet Switching Capacities (Maximum with 64 Byte Packets)
•  24P/24T: 448 Gbps
•  48P/48T: 496 Gbps
Software Specifications
Security
•  MAC limiting (per port and per VLAN)
•  Allowed MAC addresses configurable per port
•  Dynamic ARP inspection (DAI)
•  IP source guard
•  Local proxy ARP
•  Static ARP support
•  DHCP snooping
•  Captive portal
•  Persistent MAC address configurations
•  Distributed denial of service (DDoS) protection (CPU control path 
flooding protection)
Layer 2/Layer 3 Throughput (Mpps) (Maximum with  
64 Byte Packets)
•  24P/24T: 333 Mpps (wire speed)
•  48P/48T: 369 Mpps (wire speed)
Layer 2 Switching
•  Maximum MAC addresses per system: 64,000
•  Jumbo frames: 9,216 Bytes
•  Number of VLANs: 4,093
•  Virtual Spanning Tree (VST) instances: 510
•  Port-based VLAN
•  MAC-based VLAN
•  Voice VLAN
•  Physical port redundancy: Redundant trunk group (RTG)
•  Compatible with Per-VLAN Spanning Tree Plus (PVST+) 
•  Routed VLAN Interface (RVI)
•  Uplink Failure Detection (UFD)
•  ITU-T G.8032 Ethernet Ring Protection Switching
•  IEEE 802.1AB: Link Layer Discovery Protocol (LLDP)