Bosch DS937 사용자 설명서

다운로드
페이지 3
Installation/configuration notes
0 m
0 ft
7 m
7 m
25 ft
25 ft
Top View
Standard coverage varies by mounting height. 360° x
14 m (50 ft) diameter when mounted at 3.7 m (12 ft).
0 m
0 ft
7 m
25 ft
25 ft
7 m
0 m
0 ft
3 m
10 ft
Side View
Standard coverage varies by mounting height. 360° x
14 m (50 ft) diameter when mounted at 3.7 m (12 ft).
Technical specifications
Detection
Zones:
A total of 50 detection zones
Speed:
0.2 m/s ~ 5.0  m/s (0.5 ft/s ~ 15 ft/s)
Pulse Count
Selectability:
1, 2, 3, or 4 pulses
Enclosure Design
Dimensions:
12.7 cm x 3.8 cm
(5 in. x 1.5 in.)
Weight:
176 g (6.2 oz)
Environmental Considerations
Humidity:
0 to 95% humidity non-condensing
Operating
Temperature:
-10°C to +49°C (+14°F to +120°F)
For UL Listed Applications, 0°C to +49°C (+32°F to
+120°F)
Mounting
Height Range:
2.4 m to 3.7 m (8 ft to 12 ft) recommended
Outputs
Relay:
Dry Contact (NC) rated at 30 VDC, 500 mA, 10 W
maximum
Tamper Switch:
Integral NC, cover-activated
Power Requirements
Current Draw:
17 mA maximum at 12 VDC
Voltage:
9 VDC to 30 VDC, 7.5 VAC to 24 VAC
Warm-Up Period:
35 ±3 seconds
Ordering information
DS937 Panoramic Detector
Provides low profile design and 360° x 14 m (50 ft)
panoramic coverage.
Order number 
DS937
 
2 | DS937 Panoramic Detector