Installation/configuration notes
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
3 m
(10 ft)
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
1.2 m
(4 ft)
Front View
Mounted on wall above door and mounted on ceiling .
75 m (2.5 ft) in front of the door.
1.5 m
(5 ft)
3 m
(10 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
.75 m
(2.5 ft)
1.5 m
(5 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
Coverage Information
The coverage (detection area) varies depending on the
mounting height above the floor, angle of the lens, and
whether the unit is mounted on a wall above the door
or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x
10 ft) The coverage patterns for the detector at a
height of 2.3 m (7.5 ft) are shown. The coverage
pattern increases or decreases with height and
detector alignment.
Notice
When you mount the unit on the wall and the lens
points straight down, some detection zones point
toward the wall and do not detect movement.
The diagrams depict views of the coverage pattern
with the detector mounted at 2.3 m (7.5 ft) above the
floor with the lens pointed straight down. Zones that
are pointed toward the wall are not shown.
Technical specifications
Environmental
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to
+49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies in
the range from 26 MHz to 1000 MHz at
50 V/m
Complies with Environmental Class II (EN50130-5)
Mechanical
Dimensions:
4.5 cm x 17.1cm x 4.4 cm
(1.80 in. x 6.75 in. x 1.75 in.)
Material:
High impact ABS plastic enclosure
Modes
Power Loss
Default:
Programmable fail-safe or fail-secure modes.
Timer:
Programmable reset accumulative or non-reset
counting mode.
Electrical
Current Draw:
8 mA nominal standby current, 39 mA at 12 VDC in
alarm
Voltage:
12 VAC or VDC to 30 VAC or VDC
Alarm Output:
Two Form C relay contacts each rated 1 A at 30 VAC
or VDC for resistive loads
2 | DS160 Series High Performance Request‑to‑exit Detectors