Intrusion Alarm Systems | DS9360 Panoramic TriTech Detector
DS9360 Panoramic TriTech Detector
 
www.boschsecurity.com
 
 
 
 
 
 
 
 
u
Motion Analyzer II processing
u
Microwave adaptive processing
u
Self-test supervision systems
u
Changeable mirrors (two mirrors provided)
u
360° x 18 m (60 ft) diameter pattern
The ceiling mount panoramic DS9360 TriTech
®
 PIR/
Microwave Detector uses several patented processing
techniques to provide excellent catch performance
with freedom from false alarm. Supervised microwave
and PIR sections ensure that the detector is working
properly. Field replaceable mirrored optics allows it to
be mounted on ceilings from 2.5 m to 6 m (8 ft to
18 ft) in height.
Functions
Signal Processing
Uses passive infrared and microwave technologies to
provide an alarm condition when both fields of
protection are simultaneously activated. Alarm signals
must meet the signaling requirements of both
technologies to activate an alarm. Adjustable PIR and
microwave sensitivity.
PIR Signal Processing
Motion Analyzer II uses multiple thresholds and timing
windows to analyze timing, amplitude, duration and
polarity of signals to make an alarm decision. Will not
alarm on extreme levels of thermal and illumination
disturbances caused by heaters and air conditioners,
hot and cold drafts, sunlight, lightning, and moving
headlights. Two sensitivity settings are provided.
Microwave Signal Processing
Adaptive processing adjusts to background
disturbances. This helps to reduce false alarms while
maintaining catch performance.
Test Features
Two high output tri-color alarm LEDs visible from any
angle, and flash to indicate a trouble condition.
Certifications and approvals
This detector has been designed to also comply with the requirements
of:
Europe
Complies with EN50131‑1, Grade 2
Region
Certification
Australia
RCM
Europe
CE
2004/108/EC: EMC Directive and
2006/95/EC: Low-Voltage Directive;
1999/5/EC Radio equipment and Tele-
communications Terminal Equipment
(R&TTE); 2011/65/EU Restriction of the
use of certain hazardous substances in
electrical and electronic equipment
[DS9360]
EN5013
1
EN50131-2-4, Grade 2