Bosch ISN-SM-50 사용자 설명서
Tamper switch/wall tamper:
Tamper contact closed in standby
mode (opened in the event of
tampering) designed for 30 VDC,
100 mA, resistance < 45 Ohm
Test connection:
Analog integration signal
Power requirements
Power consumption
at 12 VDC:
Alarm: 6 mA
Standby: 3 mA
Power supply
monitoring:
8 VDC to 16 VDC (12 V nominal)
Alarm: < 7 VDC
Input for remote controlled reduction of sensitivity
For reduction:
Low < 1.5 VDC
High > 3.5 VDC
Reduction to:
1/8 of current setting
Trademarks
SENSTEC
®
is a registered trademark of Siemens Building Technologies.
Ordering information
ISN-SM-50 Seismic Detector
Seismic detector with 4m operating radius on concrete
and 50m
Seismic detector with 4m operating radius on concrete
and 50m
2
monitoring area.
Order number
ISN-SM-50
ISN-SM-80 Seismic Detector
Seismic detector with 5m operating radius on concrete
and 80m
Seismic detector with 5m operating radius on concrete
and 80m
2
monitoring area.
Order number
ISN-SM-80
Accessories
ISN-GMX-D7 anti-drill foil
Anti drill protection foil for use in seismic detectors.
Order number
ISN-GMX-D7 anti-drill foil
Anti drill protection foil for use in seismic detectors.
Order number
ISN-GMX-D7
ISN-GMA-S6 fixing device
For use with seismic detectors to monitor safes and
strong rooms. Consists of a detector plate, a door
plate, and a standby plate.
Order number
For use with seismic detectors to monitor safes and
strong rooms. Consists of a detector plate, a door
plate, and a standby plate.
Order number
ISN-GMA-S6
ISN-GMX-B0 floor socket
Floor box for mounting a seismic detector in the floor.
Order number
Floor box for mounting a seismic detector in the floor.
Order number
ISN-GMX-B0
ISN-GMX-P0 mounting plate
Mounting plate for seismic detectors. Suitable for
mounting seismic detectors to steel or concrete
surfaces.
Order number
Mounting plate for seismic detectors. Suitable for
mounting seismic detectors to steel or concrete
surfaces.
Order number
ISN-GMX-P0
ISN-GMX-P3S swivel plate
Swivel plate for use with ISN-SM-50 seismic detectors.
Order number
Swivel plate for use with ISN-SM-50 seismic detectors.
Order number
ISN-GMX-P3S
ISN-GMX-PZ swivel plate
Swivel plate for use with ISN-SM-80 seismic detectors.
Order number
Swivel plate for use with ISN-SM-80 seismic detectors.
Order number
ISN-GMX-PZ
ISN-GMX-S1 test transmitter
Test transmitter for installation under a seismic
detector. Checks the detector and the physical contact
between the detector and the protected object.
Order number
Test transmitter for installation under a seismic
detector. Checks the detector and the physical contact
between the detector and the protected object.
Order number
ISN-GMX-S1
ISN-GMX-W0 wall mounting kit, surface and flush mount
Wall recess set for surface or flush mounting a seismic
detector to a wall.
Order number
Wall recess set for surface or flush mounting a seismic
detector to a wall.
Order number
ISN-GMX-W0
ISN-GMXW-G0 watertight housing
Protects seismic detectors from water and dust.
Order number
Protects seismic detectors from water and dust.
Order number
ISN-GMXW-G0
ISN-GMX-P3S2 spacer (2 mm)
Spacer 2mm thick for swivel plate.
Order number
Spacer 2mm thick for swivel plate.
Order number
ISN-GMX-P3S2
ISN-GMX-P3S4 spacer (4 mm)
Spacer 4mm thick for swivel plate.
Order number
Spacer 4mm thick for swivel plate.
Order number
ISN-GMX-P3S4
Software Options
ISN-SMS-W7 SensTool PC software
Programming software for seismic detectors.
Order number
ISN-SMS-W7 SensTool PC software
Programming software for seismic detectors.
Order number
ISN-SMS-W7
3 | ISN-SM Seismic Detectors