Bosch ISN-GMX-P3S2 사용자 설명서

다운로드
페이지 4
SensTool software
SensTool software for PCs provides the following
options:
• Changing factory default settings
• Monitoring detector performance
• Storing information such as integrator signals
• Selecting additional settings for detector and shock
sensitivity
Fixing device
A fixing device is available as an optional hardware
accessory for ISN-SM seismic detectors. When the
system is armed, the fixing device monitors safes and
strong rooms for attacks using thermal and mechanical
tools, as well as unauthorized opening. The fixing
device components consist of a detector plate, a door
plate, and a standby plate.
The detector plate has a monitoring microswitch and a
magnetic contact. When the system is armed, the
monitoring switch in the detector plate is closed. If the
detector is removed from the door plate, the
monitoring switch opens and triggers an alarm.
The detector can be hung on the standby plate during
working hours.
Swivel plate
A swivel plate is available as an optional hardware
accessory for the ISN-SM seismic detector. A swivel
plate is used for monitoring safes and strong rooms
with exposed keyholes. A microswitch in the swivel
plate monitors movement. Any unauthorized swivel
movement immediately triggers an alarm. When the
system is armed, the swivel plate fully covers the
keyhole. When the system is disarmed, the swivel
plate swivels so it is at a 90° angle to the keyhole.
Certifications and approvals
 
Region
Certification
Germany
VdS
ISN-SM-50
VdS
ISN-SM-80
Europe
CE
EN 61000-6-3, 2007, Ref EN 50130-4,
1995 + A1: 1998 + A2: 2003 [ISN-
SM-50, ISN-SM-51 CHI, ISN-SM-80]
USA
UL
ANSR: Intrusion Detection Units
(UL639)
China
CCC
2011031901000203
the Nether-
lands
NCP
ISN-SM-50: 06229520/AA/00
Installation/configuration notes
Installation notes
Seismic detectors can be mounted directly onto steel
plates with smooth surfaces. The surface must not be
painted and must be level with a maximum deviation
of 0.1 mm. If these conditions cannot be met, the
MXP0 mounting plate must be used.
The seismic detector cannot be mounted directly onto
plastered or unplastered concrete.
Parts included
Number
Components
1
Seismic detector (ISN-SM-50 or ISN-SM-80)
1
Installation manual
1
Installation template
3
Cable ties
Technical specifications
Electromagnetic sensitivity
Compatibility:
Better than EN 50130-4
HF interference
tolerance
(EN 61000-4-3):
No alarm or setup at critical frequencies within a
range of 1 MHz to 1000 MHz at > 30 V/m.
Housing
Dimensions:
8.9 cm x 8.9 cm x 2.2 cm
   
Weight:
0.320 kg
Environmental conditions
Humidity (EN60721):
Up to 95% relative humidity, not
condensing
Housing protection class
(EN 60529, EN 50102):
IP435
Temperature (operating):
-40 °C to +70 °C
Temperature (storage):
-50 °C to +70 °C
Function test
For the test:
Low < 1.5 VDC
High > 3.5 VDC
Test duration (including test
transmitter ISN-GMX-S1):
≤ 3 sec
Operating radius according to monitoring area on
concrete and steel for all tools, including thermal
tools
ISN-SM-50:
4 m radius = 50 m
2
 monitoring area
 
ISN-SM-80:
5 m radius = 80 m
2
 monitoring area
 
Outputs
Alarm relay (changeover
contact):
Contact closed in standby mode
(opened in the event of an alarm)
designed for 30 VDC, 100 mA,
resistance < 20 Ohm
Alarm holding time:
Approx. 2.5 sec
2 | ISN-SM Seismic Detectors