Microwave Anti-mask
The detector sends a supervision‑trouble signal if
microwave reflective material is placed within 30.5 cm
(1 ft) of the detector.
Supervised Microwave and PIR
The detector provides single technology coverage if
the microwave subsystem fails.
Active White Light Suppression
An internal light sensor measures the level of light
intensity directed at the face of the detector. Sensor
data fusion technology uses this information to
eliminate false alarms from bright light sources.
Field Selectable Coverage (18 m x 25 m or 8 m x
10 m)
Installers can use a DIP switch to select 18 m x 25 m
or 8 m x 10 m (60 ft x 80 ft or 25 ft x 33 ft) coverage.
Dynamic Temperature Compensation
The detector automatically adjusts PIR sensitivity to
identify human intruders at critical temperatures.
Dynamic temperature compensation detects human
body heat accurately, avoids false alarms, and delivers
consistent catch performance at all operating
temperatures.
Cover and Wall Tamper Switch
When an intruder removes the cover or attempts to
separate the detector from the wall, a normally-closed
contact opens to alert the control panel.
Self-adjusting LED
The LED brightness adjusts automatically to the
surrounding light level. A blue light-emitting diode
(LED) indicates dual alarms and activates during a
walk test. A yellow LED indicates microwave alarms,
and a red LED indicates PIR alarms.
Remote Walk Test LED
Users can type a command through a keypad, a control
center, or programming software to remotely enable
or disable the walk test LED. Users can locally enable
or disable the walk test LED through the DIP switch.
Alarm Memory
Alarm memory flashes the alarm LED to indicate
stored alarms for use in multiple unit applications. A
switched voltage from the control panel controls the
alarm memory.
Solid State Relays
Solid state relays send silent alarm output signals to
provide a higher level of security and reliability. An
external magnet does not activate the relay. The solid
state relay uses less current than a mechanical relay,
providing longer standby capacity during a power loss.
Draft, Insect, and Small Animal Immunity
The sealed optic chamber provides immunity to drafts
and insects, reducing false alarms. Small animal
immunity reduces false alarms caused by animals less
than 4.5 kg (10 lb), such as rodents.
Remote Self Test
A remote self test initiates when the walk test input
switches to its true state. The alarm relay and alarm
LED activate for four seconds following a successful
test. The trouble relay activates, and the alarm LED
flashes following a failed test.
Input Power Supervision
When the power is lower than 8 V, a low input power
trouble condition activates the trouble relay and
causes the LED to flash. The trouble condition clears
automatically when power reaches or exceeds 8 V.
Trouble Memory
When the walk test input switches to its true state for
less than two seconds, LED flashes to indicate the
most recent trouble condition. If there is no trouble in
memory, the LED does not flash. After twelve hours, or
after the detector receives a second walk test pulse
for two seconds or less, the LED stops flashing and
the trouble memory clears.
Certifications and Approvals
The detectors are designed to also comply with the requirements of:
Australia
C-Tick
 
Region
Certification
Europe
CE
2004/108EC EMC Directive (EMC),
2006/95/EC Low-Voltage Directive
(LVD), 1999/5/EC Radio equipment and
Telecommunications Terminal Equip-
ment (R&TTE) [-W18G, -W18H]
USA
UL
ANSR: Intrusion Detection Units
(UL639), ANSR7: Intrusion Detection
Units Certified for Canada (cULus) [-
W18G]
FCC
(T3XISC-PDL1-W18G)
Canada
IC
(1249A-W18G)
Italy
IMQ
(CA12.00833) [-G]
Brazil
ANATEL
1282-06-1855 [-W18G]
Belgium
INCERT
B-509-0052 [-W18G]
INCERT
B-509-0052/a
China
CCC
2009031901000559 [-W18G]
the Nether-
lands
REQ
07223002/AA/00 [-W18G]
Sweden
INTYG
Nr11-850 [-W18G]
France
AFNOR
2830390400A1 [-W18H]
Belgium
INCERT
B-509-0052/c [-W18G]
France
AFNOR
2830390400B0 [-W18G]
2 | ISC‑PDL1‑W18x Professional Series TriTech Detectors