0m
12m
12m
0m
0ft
0ft
0m
0m
2m
4m
6m
8m
10m
10m
8 m
6m
4m
2m
2m
4m
6m
8m 10m 12m 14m 16m
7ft
13ft 20ft 26ft 33ft 39ft 46ft 52ft
7ft
13ft
20ft
26ft
33ft
39ft
39ft
33ft
26ft
20ft
13ft
7ft
0m
2m
4m
6m
8m 10m 12m 14m 16m
0m
2m
4m
6m
8m 10m 12m 14m 16m
0ft
7ft
13ft 20ft 26ft 33ft 39ft 46ft 52ft
0ft
7ft
13ft 20ft 26ft 33ft 39ft 46ft 52ft
0ft
0 ft
2m
3m
7ft
10ft
2
3
1
1
1
1
2
2
3
3
90°
Long-range Coverage: 16 m x 21 m (50 ft x 70 ft)
 
2
3
0 f t
0 f t
0 f t
0 f t
0 f t
0 f t
0 m
0 m
0 m
0 m
0 m
0 m
2 m
2 m
2 m
2 m
2 m
2 m
7 f t
7 f t
7 f t
7 f t
7 f t
7 f t
13 f t
13 f t
13 f t
13 f t
13 f t
26 f t
20 f t
20 f t
20 f t
26 f t
26 f t
20 f t
20 f t
4 m
4 m
4 m
4 m
4 m
6 m
6 m
6 m
6 m
6 m
8 m
8 m
10 f t
3 m
2
2
3
3
2
90°
Selectable Short-range Coverage: 8 m x 10 m
(25 ft x 33 ft)
Mounting Considerations
The recommended mounting height is 2 m to 3 m (7 ft
to 10 ft).
Use an optional B328 Gimbal-mount Bracket or B335-3
Low-profile Swivel-mount Bracket to surface-mount
the detector on a flat wall or a corner.
Use an optional B338 Universal Ceiling Bracket to
mount the detector on the ceiling.
Wiring Considerations
Recommended wire size is 0.2 mm
2
 to 1 mm
2
 (26 AWG
to 16 AWG).
Parts included
Quantity
Component
1
Detector
2
Flat-head screws
2
Screw anchors
1
Nylon cable tie
1
Pattern Mask
1
Installation Guide
Technical specifications
Electrical
Power Requirements
Voltage (Operating):
9 VDC to 15 VDC
Current (Maximum):
< 15 mA
Current (Standby):
< 10 mA at 12 VDC
Relay:
Solid state relay, normally-closed (NC)
contacts, power supervised.
3 W, 125 mA, 25 VDC,
resistance < 10 Ω
Tamper:
Normally-closed (NC) contacts (with
cover on) rated at 25 VDC, 125 mA
maximum.
Connect tamper circuit to 24-hour
protection circuit.
Mechanical
Enclosure Design
Color:
White
Dimensions:
127 mm x 69 mm x 58 mm
(5 in. x 2.75 in. x 2.25 in.)
Material:
High-impact ABS plastic
Indicators
Alarm Indicator:
Blue alarm LED
3 | ISC‑PPR1‑W16 Professional Series PIR Detector