Datalogic 94ACC0084 전단
CONNECTIONS
The Memor X3 Single Slot Dock can be connected to a host by means of a USB interface or an RS232
interface.
USB CONNECTION
The Memor X3 Single Slot Dock can be connected to the host by means of any standard Mini USB cable.
Once the host has been turned on, insert the Memor X3 mobile computer into the dock.
Figure 4 - USB Connection
A)
Host Computer
C) Memor X3 Single Slot Dock
B)
Std Mini USB (included in the dock box)
D) Power
Supply
(only necessary for battery charging)
RS232 CONNECTION
A Memor X3 Single Slot Dock can be connected to the host by means of any standard null modem cable.
The 9-pin female D-Sub connector must be connected to the RS232 port of the dock.
Once the host has been turned on, insert the Memor X3 mobile computer into the dock.
Figure 5 - RS232 Connection
A)
Host Computer
C) Memor X3 Single Slot Dock
B) Null Modem cable (i.e. 94A051020
CAB-427)
D) Power
Supply
*
(only necessary for battery charging)
.
Recommended power supply: 94ACC1324 PG5-30P35 AC/DC POWER SUPPLY EU/USA PLUG
TECHNICAL FEATURES
Memor X3 Single Slot Dock
Electrical Features
Power Supply*
Power Supply*
from 5 VDC ± 5%
Consumption
Max. 2.5 A
Indicators
Power on LED (green)
Spare battery charge LED (bi-colored)
Spare battery charge LED (bi-colored)
Charge Time
- 1100 mAh Battery: max. 2 hours spare battery only; max. 3 hours with terminal and spare
battery
battery
- 2000 mAh Battery: max. 4 hours spare battery only; max. 6 hours with terminal and spare
battery
battery
- 1430 mAh Battery: max. 3 hours spare battery only; max. 4 hours with terminal and spare
battery
battery
- 2300 mAh Battery: max. 5,5 hours spare battery only; max. 7,5 hours with terminal and
spare battery
spare battery
Communication Features
Interface
Interface
RS232, USB 1.1 version
Baud Rate
RS232 = up to 115200 b/sec; USB = up to 12 Mb/sec
Environmental Features
Working
Temperature**
Working
Temperature**
0° to +50 °C (+32° to +122 °F)
Storage Temperature
-20° to +65 °C (-4° to +149 °F)
Humidity 80%
non
condensing
Degree of Protection
IP50
Mechanical Features
Dimensions
Dimensions
105 X 75 X 80 mm (4.13 X 2.95 X 3.15 in)
Weight
256 g (9.03 oz)
*
Recommended power supply: 94ACC1324 PG5-30P35 AC/DC POWER SUPPLY EU/USA PLUG.
**
Battery must be charged at a temperature ranging from 0° to +36 °C (+32° to +97 °F).
COMPLIANCE
FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s authority
to operate the equipment.
Industry Canada (ICES-003) Compliance
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
A
B
C
D*
A
B
C
D*