HP ProLiant x64 Windows Unified Data Storage Server OS Upgrade T5322A 전단

제품 코드
T5322A
다운로드
페이지 14
3
 
Requirements 
• 
Microsoft iSCSI Software Target 
• 
Windows® Storage Server 2003 R2 or Windows Unified Data Storage Server 2003 
• 
Microsoft iSCSI Software Initiator 
 
Prerequisites 
• 
MSCS configured and running on the two nodes 
• 
Sufficient free space on the shared disk to create Microsoft iSCSI Software Target Disk(s) 
 
Note 
Throughout the rest of this document, the Windows cluster 
machines will be referred to as Node 1 and Node 2. The 
shared-disk resource to be used for creating Microsoft iSCSI 
Software Target disks will be referred to as E:\. Also, have 
the full name or IP address of the cluster available. 
 
Preparing cluster nodes
 
1. 
Use the Microsoft iSCSI Software Target installation wizard to Install Microsoft iSCSI Software 
Target on both nodes.  
Note 
If you are running Microsoft Unified Data Storage Server 
2003 on the cluster nodes, Microsoft iSCSI Software Target 
is preinstalled. 
2. 
Uncheck the Launch Microsoft iSCSI Software Target check box on the final page of the 
wizard so that the iSCSI Target Console does not open when the installation is complete.  
3. 
Stop the Microsoft iSCSI Software Target service by issuing net stop wintarget on the 
command line on both cluster nodes.