Tandberg Data StorageLoader 2U LTO, 1 x 10 LTO-3 052102 사용자 설명서

제품 코드
052102
다운로드
페이지 278
A
PRIL
 2007
S
TORAGE
L
OADER
 2U LTO
209
P
ERFORMANCE
 S
PECIFICATIONS
L
IBRARY
 P
OWER
-O
N
 S
EQUENCE
 T
IME
Each time the library is powered on, it performs a sequence of activities. 
During its power-on sequence, the library:

Performs a power-on self-test (POST)

Runs self-diagnostics

Establishes communication with the tape drive(s)

Verifies the SCSI IDs

Performs a cartridge inventory
The time required for the power-on sequence is measured from the time 
power is applied until the library indicates ready status.
The library’s power-on sequence time is approximately10 seconds when the 
library contains 20 cartridges with or without bar code labels.
C
ARTRIDGE
 I
NVENTORY
 
An application can issue a command to the library to check all cells for 
cartridges and scan bar code labels. After checking the cells, the library 
updates its cartridge inventory.
The average cartridge inventory time is approximately:

100 seconds when the library contains 20 cartridges with bar code labels.

1200 seconds when the library contains 20 cartridges without bar code 
labels.
I/E P
ORT
 I
NVENTORY
 
Whenever a cartridge is inserted or removed through the I/E port, the library 
performs a cartridge inventory on the affected cell.
The average time for an individual cartridge cell inventory is:

15 seconds when the cartridge has a bar code label.

50 seconds when the cartridge does not have a bar code label.
M
OVE
 C
OMPLETE
 T
IME
Move complete time is the time it takes the library to remove a cartridge from a 
tape drive, return it to its cell, and load the new cartridge into the tape drive.
Move complete time is measured from the time the library receives the move 
command to the time the library returns status to the initiator indicating that 
the move is complete. The average move complete time is approximately 
150 seconds. Worst case time to complete this command is 10 minutes.