Tandberg Data StorageLoader 2U LTO, 1 x 10 LTO-3 052102 사용자 설명서

제품 코드
052102
다운로드
페이지 278
20
P
RODUCT
 M
ANUAL
 
1016988
C
HAPTER
 2—I
NSTALLING
 
THE
 L
IBRARY
C
ONNECTING
 
THE
 L
IBRARY
 
TO
 F
IBRE
 C
HANNEL
This section provides instructions for connecting the tape drive(s) in the 
library to a Fibre Channel network.
 shows the back panel of the StorageLoader 2U LTO FC Library. 
Each tape drive includes one integrated dual LC optical fiber connector, 
Port A, for connecting the tape drive to a Fibre Channel network.
In a Fibre Channel environment, you can connect the tape drive(s) to a Fibre 
Channel hub or switch in an arbitrated loop or a switched fabric. For simplicity 
in these instructions, each of these situations is referred to as a “network.”
To connect the tape drive(s) to a Fibre Channel network:
1.
1.
1.
1.
Remove the tape over the Fibre Channel connector. The tape secures the 
protective plugs.
2.
2.
2.
2.
Remove the protective plugs from the optical connectors on each tape 
drive. Set the plugs aside. 
3.
3.
3.
3.
Attach an optical cable from the hub or switch to the optical fiber connector 
on each tape drive (if more than one tape drive is installed). The connector 
and the cable are keyed to ensure that the cable is attached in the correct 
orientation.
Note:
Once the library has been powered on and the Fibre Channel loop has 
been initialized, avoid disconnecting the tape drive in the library from the 
loop. If you need to disconnect the library from the loop, use the utility 
provided with your switch or hub to bypass the affected ports before 
breaking the connection. The bypass sets the port to a non-participating 
state on the loop. When you have reconnected the library, use the utility 
to return the port to a participating state.
Figure 2-7 Fibre Channel connector
FC connector