Tandberg Data StorageLoader 2U LTO, 1 x 20 LTO-3 052103 사용자 설명서
제품 코드
052103
190
P
RODUCT
M
ANUAL
1016988
C
HAPTER
7—M
AINTENANCE
5.
5.
5.
5.
If necessary, rename the firmware file(s) you downloaded from
as follows:
Library firmware: Change “filename.bin” to “libflash.bin”
Ethernet module firmware: Change “filename.hex” to “enet.hex”
Use the FTP command for your utility to transfer the new firmware to
the library. For example, issue a “put libflash.bin” command.
The system initiates the firmware upgrade and displays its progress on the
library’s LCD. When the upgrade has completed successfully, the library
automatically resets.
C
REATING
A
D
IAGNOSTIC
L
ISTING
VIA
FTP
To create a diagnostic listing via FTP:
1.
1.
1.
1.
Connect to the library’s FTP interface by following the instructions on
.
2.
2.
2.
2.
Make sure that the FTP file transfer type is set to binary.
3.
3.
3.
3.
Use the FTP command for your utility to get the diagnostic listing.
For example, issue the “get libdump.bin” command.
4.
4.
4.
4.
If necessary, specify a destination location (path and filename) for the
diagnostic listing.
L
IB
T
OOL
—L
IBRARY
F
IRMWARE
U
PGRADE
You can also use LibTool to upgrade firmware over the SCSI interface.
LibTool is available as a free download at
.
Refer to the readme file provided with the program for installation
instructions.
Refer to the program’s online help for instructions on performing
upgrades and diagnostics.
You can download new firmware at
USB P
ORT
—L
IBRARY
F
IRMWARE
U
PGRADE
AND
D
IAGNOSTICS
You can use the USB port to upgrade library firmware and create diagnostic
listings. See
Caution
Do not attempt to perform library operations or power down the library until after
it automatically resets.