Rigol DS2102A 2-channel oscilloscope, Digital Storage oscilloscope, DS2102A 사용자 설명서
제품 코드
DS2102A
RIGOL
DS2000A User’s Guide
1-7
Tip
The signal output from the probe compensation connector can only be used for
probe compensation adjustment and can not be used for calibration.
Probe Compensation
When the probes are used for the first time, you should compensate the probes to
match the input channels of the oscilloscope. Non-compensated or poorly
compensated probes may cause measurement inaccuracy or error. The probe
compensation procedures are as follows.
1. Perform steps 1, 2, 3 and 4 of
2. Check the waveforms displayed and compare them with the following.
Figure 1-8 Probe Compensation
3. Use a nonmetallic driver to adjust the low-frequency compensation adjustment
hole on the probe until the waveform displayed is as the “Perfectly compensated”
in the figure above.
in the figure above.
Over compensated Perfectly compensated Under compensated