Lecroy HDO4034 4-channel oscilloscope, Digital Storage oscilloscope, Bandwidth 350 MHz HDO4034 데이터 시트
제품 코드
HDO4034
Ordering Information
Quickly locate analog or digital
waveforms for runts, glitches or
other anomlies with WaveScan.
Excellent Performance
– 200 MHz, 350 MHz, 500 MHz, 1 GHz
– 2.5 GS/s maximum sample rate
– Up to 25 Mpts / 50 Mpts (interleaved)
– 12-bit ADC resolution, 15-bit with ERES
– 2.5 GS/s maximum sample rate
– Up to 25 Mpts / 50 Mpts (interleaved)
– 12-bit ADC resolution, 15-bit with ERES
Rich Feature Set
– WaveScan™ search and find
– History Mode waveform playback
– LabNotebook™ report generator
Wide Range of Serial Data Tools
– I
2
C, SPI, UART
– CAN, LIN, FlexRay™, SENT
– USB 1.0/1.1/2.0, USB 2.0 HSIC
– Audio (I
2
S, LJ, RJ, TDM)
– MIL-STD-1553, ARINC 429
– MIPI D-PHY, DigRF 3G, DigRF v4
hdo4kFact-Sheet-21sept12
PDF
Easily control channels, trigger,
math and measurements with the
large multi-touch display and
intuitive interface.
Use History Mode to scroll back in
time to isolate anomalies and quickly
find the source of the problem.
Available Probes
Single-Ended
High-Voltage
ZS1500
1.5 GHz, 0.9 pF, 1 M
Ω High Impedance Active Probe
PPE1.2KV
10:1/100:1 200/300 MHz 50 M
Ω High-Voltage Probe 600V/1.2kV Max. Volt. DC
ZS1000
1 GHz, 0.9 pF, 1 M
Ω High Impedance Active Probe
PPE2KV
100:1 400 MHz 50 M
Ω 2 kV High-Voltage Probe
PPE4KV
100:1 400 MHz 50 M
Ω 4kV High-Voltage Probe
Differential
PPE5KV
1000:1 400 MHz 50 M
Ω 5 kV High-Voltage Probe
ADP300
1,400 V, 20 MHz High-Voltage Differential Probe
PPE6KV
1000:1 400 MHz 50 M
Ω 6 kV High-Voltage Probe
ADP305
1,400 V, 100 MHz High-Voltage Differential Probe
PPE20KV
1000:1 100 MHz 50 M
Ω High-Voltage Probe 20kV Max. Volt. DC + 40kV Peak AC
AP031
700 V, 15 MHz High-Voltage Differential Probe
ZD200
200 MHz Active Differential Probe
ZD500
500 MHz Active Differential Probe
Current
ZD1000
1 GHz Active Differential Probe
AP015
30 A; 50 MHz Current Probe – AC/DC; 30 A
rms
; 50 A
peak
Pulse
ZD1500
1.5 GHz Active Differential Probe
CP030
30 A; 50 MHz Current Probe – AC/DC; 30 A
rms
; 50 A
peak
Pulse
CP031
30 A; 100 MHz Current Probe – AC/DC; 30 A
rms
; 50 A
peak
Pulse
Differential Amplifiers
CP150
150 A; 10 MHz Current Probe – AC/DC; 150 A
rms
; 50 A
peak
Pulse
DA1855A
1 Ch, 100 MHz Differential Amplifier
CP500
500 A; 2 MHz Current Probe – AC/DC; 500 A
rms
; 700 A
peak
Pulse
DXC100A
100:1 or 10:1 Selectable, 250 MHz Passive
Differential Probe Pair
Model
Bandwidth
Channel
Memory
(per Ch / interleaved)
Sample Rate
(per Ch / interleaved)
HDO4022
200 MHz
2
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4024
200 MHz
4
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4032
350 MHz
2
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4034
350 MHz
4
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4054
500 MHz
4
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4104
1 GHz
4
12.5 Mpts / 25 Mpts
2.5 GS/s / 2.5 GS/s
HDO4000 Oscilloscopes Fact Sheet