Fluke 1654B06-TPOLEKIT/DVDE-tester 4425949 사용자 설명서

제품 코드
4425949
다운로드
페이지 66
1652C/1653B/1654B 
Users Manual 
50 
Earth Tests (R
E
Limit Value 
Maximum Display 
Value 
Limit Value 
Maximum Display 
Value 
10 8.8 
200 179.8 
20 17.8  300 268.0 
30 26.8  400 358.0 
40 35.8  500 448.0 
50 44.8  600 538.0 
60 53.8  700 628.0 
70 62.8  800 718.0 
80 71.8  900 808.0 
90 80.8  1000 
898.0 
100 89.8 
2000 1798.0 
AC Voltage Measurement (V) 
Range Resolution 
Accuracy 
50 Hz – 60 Hz 
Input Impedance 
Overload Protection 
500 V 
0.1 V 
0.8 % + 3 
3.3 M
Ω
 
660 V rms 
Continuity Testing (R
LO
Range 
(Autoranging) 
Resolution  Open Circuit Voltage 
Accuracy 
20 
Ω
 0.01 
Ω
 
>4 V 
±
(1.5 % + 3 digits) 
200 
Ω
  
0.1 
Ω
 
>4 V 
±
(1.5 % + 3 digits) 
2000 
Ω
 1 
Ω
 
>4 V 
±
(1.5 % + 3 digits) 
Note 
The number of possible continuity tests with a fresh set of batteries is 3000. 
 
Range RLO Test 
Current 
7.5 Ω 210 
mA 
35 Ω 100 
mA 
240 Ω 20 
mA 
2000 Ω 2 
mA 
 
Test Probe Zeroing 
Press the  to zero the test probe. 
Can subtract up to 2 
Ω
 of lead resistance. 
Error message for >2 
Ω
Live Circuit Detection 
Inhibits test if terminal voltage >10 V ac detected prior to 
initiation of test.