Voltcraft LT-100Tester LT-100 사용자 설명서

제품 코드
LT-100
다운로드
페이지 56
27
12. tEChNICaL data
Test interval “TEST“ ..............................Approximately 1 second
Test voltage ..........................................max. 3000 V/AC, 68 kHz - 72 kHz
Telescopic antenna length ....................approx. 68 cm
Heating coil test ....................................T2, T4, T5, T8, T9, T10, T12
Automatic switch off ..............................5 minutes
Power supply ........................................4 micro batteries (AAA)
Power consumption ..............................approximately 400 mA (Impulse)
Work conditions ....................................0 to 40°C / <75 %rF (not condensing)
Storage conditions ................................-10 to +50°C / <75 %rF (not condensing)
Operational height ................................max. 2000 m
Battery change alarm ...........................<4.5 V, acoustic
Alarm signal ..........................................>70 dB
Measurements (LxBxH) ........................220 x 55 x 30 (mm)
Weight ..................................................approx. 226 g
Measuring category ..............................CAT II 300 V
Contamination level ..............................2
   Never exceed the maximum input values permitted. do not touch any circuitry or connection 
points when voltages exceeding 33 v/aCrms or 70 v/dC might be applied. risk of fatal injury!