Emmerich Li-ion battery ICR-18650 NQ-SP 3.7 V 2600 mAh (Ø x H) 18.4 mm x 70 mm 233974 데이터 시트

제품 코드
233974
다운로드
페이지 6
Material Safety Data Sheet 
  Reference  number:  DBK20110101 
 
  Issue date: 2011-1-01        Rev: 2011-01 
 
Skin contact: The electrolyte solution contained in the battery causes skin irritation. 
Ingestion: The ingestion of electrolyte solution causes tissue damage to throat and 
gastro/respiratory tract. 
Inhalation:  Contents  of  a  leaking  or  ruptured  battery  can  cause  respiratory  tract, 
mucus, membrane irritation and edema. 
Special protective equipment: 
Use self-contained breathing apparatus to avoid breathing irritant fumes. 
Wear  protective  clothing  and  equipment  to  prevent  body  contact  with  electrolyte 
solution. 
6. Accidental Release Measures 
The  material  contained  within  the  batteries  would  only  be  expelled  under  abusive  conditions.  Using  shovel  or  broom,  cover 
battery or spilled substances with dry sand or vermiculite, place in approved container (after cooling if necessary) and dispose 
in accordance with local    regulations. 
7. Handling and Storage 
The batteries should not be opened destroyed or incinerated since they may leak or rupture and release in the environment the 
ingredients they contain. 
       
Handling 
Do  not crush, pierce,  short  (+)  and  (-)  battery  terminals  with  conductive  (i.e.  metal)  goods. 
Do not directly heat or solder. Do not throw into fire. Do not mix batteries of different types and 
brands. Do not mix new and used batteries. Keep batteries in non-conductive (i.e. plastic) trays.
 
Storage 
Store in a cool (preferably below 30°C) and ventilated area away from moisture, sources of 
heat, open flames, food and drink. Keep adequate clearance between walls and batteries. 
Temperature above 90°C may result in battery leakage and rupture. Since short circuit can 
cause burn, leakage and rupture hazard, keep batteries in original packaging until use and do 
not jumble them. 
 
Other 
manufacturer recommendations regarding maximum recommended currents and operating 
temperature range. 
Applying pressure on deforming the battery may lead to disassembly followed by eye, skin 
and throat irritation. 
8. Exposure Controls/personal Protection 
Respiratory protection: 
Not necessary under normal use. 
In  case  of  battery  rupture,  use  self-contained  full-face 
respiratory equipment. Equip with type ABEK filter. 
Hand protection: 
Not necessary under normal use.   
Use rubber gloves if handling a leaking or ruptured battery. 
Eye protection: 
Not necessary under normal use. Wear safety goggles or 
glasses  with  side  shields  if  handling  a  leaking  or  ruptured 
battery. 
Skin protection: 
Not necessary under normal use.    Use rubber apron and 
protective working in case of handling of a ruptured battery. 
9. physical And Chemical Properties 
    9.1 Appearance (Physical shape and color as supplied:) 
  Metal squares, hermetically sealed and fitted with an external plastic box. 
9.2  Temperature    range 
 
Temperature    range