Phoenix Contact Sensor/Actuator cable SAC-5P-MS/10,0-186 SCO 1518342 1518342 데이터 시트

제품 코드
1518342
다운로드
페이지 6
Nov 12, 2013    2 / 6
Technical data
General
Insertion/withdrawal cycles
≥ 100
Material
Inflammability class according to UL 94
HB
Contact material
CuSn
Contact surface material
Ni/Au
Contact carrier material
TPU GF
Material of grip body
TPU, hardly inflammable, self-extinguishing
Material, knurls
Zinc die-cast, nickel-plated
Cable
Cable type
PUR POWER 0.75 mm² black
Cable type (abbreviation)
186
Cable abbreviation
LiY11Y
Conductor cross section
5x 0.75 mm² (power line)
AWG signal line
18
Conductor structure signal line
42x 0.15 mm
Core diameter including insulation
1.7 mm ±0.05 mm
Thickness, insulation
≥ 0.23 mm (Core insulation)
Thickness, insulation
≥ 0.76 mm (Outer cable sheath)
Wire colors
Brown, white, blue, black, gray
Overall twist
5 wires around filler to the core
External sheath, color
Black-gray RAL 7021
External cable diameter D
6.3 mm ± 0.2 mm
Smallest bending radius, movable installation
63 mm
Number of bending cycles
2000000
Bending radius
63 mm
Traversing path
5 m
Traversing rate
3 m/s
Acceleration
5 m/s²
Cable weight
67 kg/km
Outer sheath, material
PUR
Material conductor insulation
PVC
Conductor material
Bare Cu litz wires
Insulation resistance
≥ 1 MΩ*km (at 20 °C)
Conductor resistance
max. 26 Ω/km (at 20 °C)
Nominal voltage, cable
≤ 300 V
Test voltage, cable
≥ 3000 V
Flame resistance
in accordance with DIN UL-Style 20549
Ambient temperature (operation)
-25 °C ... 80 °C (cable, fixed installation)
Ambient temperature (operation)
-5 °C ... 80 °C (cable, flexible installation)