Panasonic RT3S24 Narrow, Compact Relay Housing With 4 Outputs RT3S24 데이터 시트
제품 코드
RT3S24
CAUTIONS FOR USE
750
ACCESSORIES
mm
inch
9. Transporting and storage
1) If the product is subjected to extreme
vibration while being transported, the
relays may become detached, the lead
may become bent, and the unit may
become damaged. Handle the inner and
outer boxes with care.
2) If the product is stored in an extremely
adverse environment, visible defects and
deterioration of performance
characteristics may result. We
recommend the following storage
conditions.
• Temperature: 5 to 30
1) If the product is subjected to extreme
vibration while being transported, the
relays may become detached, the lead
may become bent, and the unit may
become damaged. Handle the inner and
outer boxes with care.
2) If the product is stored in an extremely
adverse environment, visible defects and
deterioration of performance
characteristics may result. We
recommend the following storage
conditions.
• Temperature: 5 to 30
°C
41 to 86
°F
• Humidity: Max. 60% R.H.
• Environment: No hazardous substances
• Environment: No hazardous substances
such as sulfurous acid gases and little
dust.
dust.
10. When equipped with Power
PhotoMOS relay voltage drive type
Since the Power PhotoMOS relay voltage
drive type does not require the current-
controlling resistance on the input side, it
can be used together with PA relays on 4-
point unit relays (PA relay types) or RT-2
relay terminals.
When connecting Power PhotoMOS
relay voltage drive types, since it will be a
close connection, it will be necessary to
be careful of load currents. Be sure to
refer to the information given regarding
load currents and ambient temperature
characteristics in the precautions given
for use of RT-2 relay terminals.
PhotoMOS relay voltage drive type
Since the Power PhotoMOS relay voltage
drive type does not require the current-
controlling resistance on the input side, it
can be used together with PA relays on 4-
point unit relays (PA relay types) or RT-2
relay terminals.
When connecting Power PhotoMOS
relay voltage drive types, since it will be a
close connection, it will be necessary to
be careful of load currents. Be sure to
refer to the information given regarding
load currents and ambient temperature
characteristics in the precautions given
for use of RT-2 relay terminals.
TERMINAL BLOCK
We recommend using wire-pressed terminals for connection to
the terminal portion.
• Applicable electrical wire
the terminal portion.
• Applicable electrical wire
0.25 to 1.65 mm
2
.01 to .065 inch
• Applicable wire-pressed terminals
mm
inch
Company Name
Part Name
Part Name
J.S.T. Mfg Co., Ltd.
1.25 to C3A
1.25 to 3
NICHIFU
1.25Y to 3N
1.25 to 3
Nippon Tanshi Co., Ltd.
VD1.25 to 3
R1.25 to 3
3 min.
.118 min.
5.6 max.
.220 max.
4.5 min.
.177 min.
4
.157
3 dia. min.
.118 dia. min.
5.6 max.
.220 max.
4.5 min.
.117 min.
4
.157
Short circuit plate
Use when you want to bridge terminals.
Use when you want to bridge terminals.
< With insulator >
AY3802
General tolerance
±0.5
±.020
< Without insulator >
AY3803
General tolerance
±0.5
±.020
13.8
.543
17.8
.701
5.8
±0.1
7.62
±0.3
.300
±.012
+0.5
−1
28
+.020
−.039
1.102
8
+0
−3
.315
3.1
±0.1
.228
±.004
.122
±.004
R
28.7
1.130
0.5
.020
1.5 to 2.5
.059 to .098
+0
−.118
13
.512
17
.669
5.8
±0.1
7.62
±0.3
.300
±.012
26.5
1.043
3.1
±0.1
.228
±.004
.122
±.004
R
28.7
1.130
0.5
.020