Panasonic PA1A-5V PCB Mount Relay PA1A-5V 데이터 시트
제품 코드
PA1A-5V
PA(D)
1
ds_61C10_en_pa: 131113D
ORDERING INFORMATION
TYPES
Standard packing: Carton: 25 pcs.; Case: 1,000 pcs.
* For sockets, see page 6.
* For sockets, see page 6.
1a 5 A slim power relay for
interface
PA(D) RELAYS
Contact arrangement
Nominal coil voltage
Part No.
PA type
PAD type
1 Form A
4.5V DC
PA1a-4.5V
—
5.0V DC
PA1a-5V
PAD1a-5V
6.0V DC
PA1a-6V
—
9.0V DC
PA1a-9V
—
12.0V DC
PA1a-12V
PAD1a-12V
18.0V DC
PA1a-18V
PAD1a-18V
24.0V DC
PA1a-24V
PAD1a-24V
24.0V DC
PA1aS-24V
—
FEATURES
1. Slim size (width 5 mm
.197 inch
,
height 12.5 mm
.492 inch
) permits
higher density mounting
Despite the slim 5 mm width, the 20 mm
length is still compact and the 12.5 mm
profile is low. Even when a socket is
used, the height is still only 18 mm.
Suitable for high-density mounting, these
relays enable device size smaller.
2. Nominal operating power: High
sensitivity of 120mW
Enables smaller power supplies,
facilitates energy saving applications,
and contributes to device size smaller.
Despite the slim 5 mm width, the 20 mm
length is still compact and the 12.5 mm
profile is low. Even when a socket is
used, the height is still only 18 mm.
Suitable for high-density mounting, these
relays enable device size smaller.
2. Nominal operating power: High
sensitivity of 120mW
Enables smaller power supplies,
facilitates energy saving applications,
and contributes to device size smaller.
3. Control from low level loads to 5 A
Use of gold-clad twin contacts enables
control of low level loads down to 100 mV
100
Use of gold-clad twin contacts enables
control of low level loads down to 100 mV
100
A and up to 5 A 250 V AC and 30 V
DC.
4. Reinforced according to IEC1131-2
(TÜV)
PAD type Min. 3.0 mm/
PA type Min. 2.0 mm clearance
PAD type Min. 3.0 mm/
PA type Min. 3.0 mm creepage distance
5. High surge breakdown voltage
(4000 V) and high breakdown voltage
(2000 V)
Between contacts and coil of 2,000 V and
surge resistance of 4,000 V work to
prevent controller malfunctions caused
by noise and surges.
6. Outstanding vibration and shock
resistance.
Functional shock resistance: 147 m/s
4. Reinforced according to IEC1131-2
(TÜV)
PAD type Min. 3.0 mm/
PA type Min. 2.0 mm clearance
PAD type Min. 3.0 mm/
PA type Min. 3.0 mm creepage distance
5. High surge breakdown voltage
(4000 V) and high breakdown voltage
(2000 V)
Between contacts and coil of 2,000 V and
surge resistance of 4,000 V work to
prevent controller malfunctions caused
by noise and surges.
6. Outstanding vibration and shock
resistance.
Functional shock resistance: 147 m/s
2
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
2.5 mm
10 to 55 Hz (at double amplitude of
2.5 mm
.098 inch
)
Keeps equipment from misoperation due
to vibration and shock.
to vibration and shock.
Can be used as mounted on control
panel doors.
7. Sealed construction allows
automatic washing.
8. SIL (single in line) terminal layout
9. Complies with safety standards
Complies with Japanese Electrical
Appliance and Material Safety Law, and
certified by UL, CSA, and TÜV.
10. Sockets are also available
panel doors.
7. Sealed construction allows
automatic washing.
8. SIL (single in line) terminal layout
9. Complies with safety standards
Complies with Japanese Electrical
Appliance and Material Safety Law, and
certified by UL, CSA, and TÜV.
10. Sockets are also available
TYPICAL APPLICATIONS
1. Industrial equipment, office
equipment
2. Measuring devices and test
equipment
3. Interface relays for programmable
controllers
4. Output relays in small devices such
as timers, counters, sensors, and
temperature controllers.
equipment
2. Measuring devices and test
equipment
3. Interface relays for programmable
controllers
4. Output relays in small devices such
as timers, counters, sensors, and
temperature controllers.
Contact arrangement
1a: 1 Form A (Bifurcated)
1a: 1 Form A (Bifurcated)
PA(D) 1a
Coil voltage (DC)
4.5, 5, 6, 9, 12, 18, 24V
4.5, 5, 6, 9, 12, 18, 24V
Notes: 1) The PAD type offers slightly higher clearance (min. 3.0 mm) and creepage distance (min. 3.0 mm).
2) UL/CSA, TÜV approved type is standard.