Panasonic ST-PS Relay Socket For ST Relay ST-PS 데이터 시트

제품 코드
ST-PS
다운로드
페이지 5
ST
1
ds_61108_0000_en_st: 091006D
SPECIFICATIONS
TYPICAL APPLICATIONS
IC DRIVABLE PC BOARD 
RELAY FOR FIELD LOAD 
SWITCHING
ST RELAYS
VDE
mm 
inch
11.3
.445
14
.551
31
1.220
FEATURES
• Sealed to meet the combination 
process of automatic wave soldering 
and cleaning needs
• Latching types available
• High switching capacity and high 
sensitivity in subminiature size
150 mW pick-up, 8 A inrush capacity: 
51 A for 1a1b, 35 A for 2a
• High shock and vibration resistance 
Shock: 20 G, Vibration: 10 to 55 Hz at 
double amplitude of 2 mm
Contacts
Coil (polarized) (at 25
°
77
°F
)
#1 This value can change due to the switching frequency, environmental conditions, 
and desired reliability level, therefore it is recommended to check this with the 
actual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section
*
2
Detection current: 10 mA
*
3
Wave is standard shock voltage of 
±1.2 × 50μs according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Half-wave pulse of sine wave: 11ms; detection time: 10
μs
*
6
Half-wave pulse of sine wave: 6ms
*
7
Detection time: 10
μs
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in 
Characteristics (at 25
°
77
°F
 50% Relative humidity)
Arrangement
1 Form A  
1 Form B
2 Form A
Contact material
Au-flashed AgCdO
Initial contact resistance, max.
30 m
Ω
Rating
(resistive)
Max. switching power
2,000 VA, 150 W
Max. switching voltage
380 V AC, 250 V DC
Max. switching current
8 A
Min. switching capacity
#1
100 mA, 5 V DC
HP rating
1/4 HP 125, 250 V AC
Inrush current capability
51 A (TV-3 equivalence) for 1a1b
35 A (TV-1 equivalence) for 2a
Expected 
life (min. 
operations)
Mechanical (at 180 cpm)
10
7
Electrical
8 A 250 V AC 
(resistive)
10
5
5 A 30 V DC (resistive)
× 10
5
3 A 100 V AC (lamp)
× 10
4
1 A 100 V AC (lamp)
× 10
4
Single side stable
Nominal operating power
Approx. 240 mW
Latching
Nominal set and reset power
Approx. 240 mW
Max. operating speed
20 cpm (at rated load)
Initial insulation resistance*
1
1,000 M
Ω (at 500 V DC)
Initial 
breakdown 
voltage*
2
Between contact sets
2,000 Vrms
Between open contacts
1,200 Vrms
Between contacts and coil
3,750 Vrms
Surge voltage between coil and 
contact*
3
Min. 6,000 V
Operate time*
4
 
(at nominal voltage)
Max. 15 ms (Approx. 10 ms)
Release time (without diode)*
4
 
(at nominal voltage)
Max. 10 ms (Approx. 8 ms)
Set time*
4
 (latching) 
(at nominal voltage)
Max. 10 ms (Approx. 8 ms)
Reset time*
4
 (latching) 
(at nominal voltage)
Max. 10 ms (Approx. 8 ms)
Temperature rise 
(at 60
°C)
Max. 55
°C with nominal coil voltage 
and at 8 A switching current
Shock 
resistance
Functional*
5
Min. 196 m/s
2
 {20 G}
Destructive*
6
Min. 980 m/s
2
 {100 G}
Vibration 
resistance
Functional*
7
117.6 m/s
2
 {12 G}, 10 to 55 Hz 
at double amplitude of 2 mm
Destructive
176.4 m/s
2
 {18 G}, 10 to 55 Hz 
at double amplitude of 3 mm
Conditions for operation, 
transport and storage*
8
(Not freezing and condens-
ing at low temperature)
Ambient 
temp.
–40
°C to +60°C
–40
°Fto +140°F
Humidity
5 to 85% R.H.
Unit weight
Approx. 10g .
353 oz
Sequence controllers, facsimiles, telephone controls, remote 