Conrad Energy 12V Ah lead acid battery, 250914 데이터 시트
제품 코드
250914
CP1250
12V 5Ah(20hr)
The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.
is absorbed by separators and plates and thus immobilized. Should the battery be
accidentally overcharged producing hydrogen and oxygen, special one-way valves allow the
gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is
completely sealed and is, therefore, maintenance-free, leak proof and usable in any position.
Battery Construction
Component
Positive plate
Negative plate
Container
Cover
Safety valve
Terminal
Separator
Electrolyte
Raw material
Lead dioxide
Lead
ABS
ABS
Rubber
Copper
F berglass
Sulfuric acid
General Features
●
Absorbent Glass Mat (AGM) technology
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
for efficient gas recombination of up to
99% and freedom from electrolyte
maintenance or water adding.
●
Not restricted for air transport-complies
with IATA/ICAO Special Provision A67.
with IATA/ICAO Special Provision A67.
●
UL-recognized component.
●
Can be mounted in any orientation.
●
Computer designed lead, calcium tin alloy
grid for high power density.
grid for high power density.
●
Long service life, float or cyclic
applications.
applications.
●
Maintenance-free operation.
●
Low self discharge.
Dimensions and Weight
Length(mm / inch)
90 / 3.54
Width(mm / inch)
70 / 2.76
Height(mm / inch)
101 / 3.98
Total Height(mm / inch)
107 / 4.21
Approx. Weight(Kg / lbs)
1.8 / 3.97
Performance Characteristics
Nominal Voltage
12V
Number of cell
6
Design Life
3~5 years
Nominal Capacity 77
o
F(25
o
C)
20 hour rate (0.25A, 10.5V)
5Ah
10 hour rate (0.47A, 10.5V)
4.7Ah
5 hour rate (0.85A, 10.5V)
4.25Ah
1 hour rate (3.25A, 9.6V)
3.25Ah
Internal Resistance
Fully Charged battery 77
o
F(25
o
C)
34mOhms
Self-Discharge
3% of capacity declined per month at 20
o
C(average)
Operating Temperature Range
Discharge
-20~60
o
C
Charge
-10~60
o
C
Storage
-20~60
o
C
Max. Discharge Current 77
o
F(25
o
C)
75A(5s)
Short Circuit Current
250A
Charge Methods: Constant Voltage Charge 77
o
F(25
o
C)
Cycle use
14.5-14.9V
Maximum charging current
2A
Temperature compensation
-30mV/
o
C
Standby use
13.6-13.8V
Temperature compensation
-20mV/
o
C
Discharge Constant Current (Amperes at 77
o
F25
o
C)
End Point
Volts/Cell
5min 10min 15min 30min
1h
3h
5h
10h
20h
1.60V
21.0
12.5 10.00 5.50
3.25
1.39
0.92
0.50
0.26
1.65V
19.9
11.9
9.56
5.28
3.13
1.35
0.90
0.49
0.26
1.70V
18.8
11.3
9.10
5.05
3.01
1.30
0.88
0.48
0.25
1.75V
17.6
10.6
8.63
4.81
2.88
1.25
0.85
0.47
0.25
1.80V
16.4
10.0
8.14
4.56
2.74
1.19
0.82
0.46
0.25
Discharge Constant Power (Watts at 77
o
F25
o
C)
End Point
Volts/Cell
5min 10min 15min 30min 45min
1h
2h
3h
5h
1.60V
35.0
23.3
18.2
10.3
8.0
6.3
3.73
2.63
1.80
1.65V
32.8
22.0
17.3
9.7
7.6
6.1
3.62
2.56
1.77
1.70V
30.7
20.6
16.4
9.1
7.3
5.8
3.50
2.49
1.74
1.75V
28.5
19.3
15.4
8.6
6.9
5.5
3.36
2.42
1.70
1.80V
26.4
17.9
14.3
8.1
6.5
5.2
3.22
2.33
1.66
page1 of 2
(Note)The above characteristics data are average values obtained within
three charge/discharge cycles not the mimimum values.
three charge/discharge cycles not the mimimum values.