Phoenix Contact Head-mounted transducer MCR-FL-HT-TS-I-EX 2864545 2864545 데이터 시트

제품 코드
2864545
다운로드
페이지 7
Nov 13, 2013    1 / 7
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
MCR head-mounted temperature transducers for resistance thermometers, thermocouples,
resistance-type sensors and voltage sensors. For Pt 100 resistance thermometers
 
Product Features
 Input for resistance thermometers, thermocouples, and linear mV signals, Ex ia IIC
 Configuration via software
 Can be installed in zone 1
 Single-channel
 Loop-powered
 4 
20 mA/20 
4 mA output
 HART-compatible (MCR-FL-TS-LP-I-EX)
 2-way electrical isolation
  
Key commercial data
package_quantity
1
GTIN
4017918893200
Technical data
Ambient conditions
Degree of protection
IP00, IP66 (integrated in the connecting head)
Input data
Configurable/programmable
Yes, programmable
Sensor types (RTD) that can be used
Pt, Ni (100, 500, 1000); min. measurement range 10 K
Sensor types that can be used (TC)
B, C, D, E, J, K, L, N, R, S, T, U; min. measurement range 50
K/500 K
Connection method
2, 3, 4-wire
Input signal range
10 Ω ... 400 Ω (min. measurement range 10 Ω)
Input signal range
10 Ω ... 2000 Ω (min. measurement range 100 Ω)
Input signal range
-10 mV ... 75 mV (min. measurement range 5 mV)
Output data