Technical data
Coil side
Nominal input current at U
IN
4.5 mA (for 230 V AC)
Typical response time
7 ms
Typical release time
10 ms
Operating voltage display
Yellow LED
Protective circuit
Bridge rectifier Bridge rectifier
Contact side
Contact type
1 PDT
Contact material
AgNi
Maximum switching voltage
250 V AC/DC (The separating plate PLC-ATP should be installed
for voltages larger than 250 V (L1, L2, L3) between identical
terminal blocks in adjacent modules. Potential bridging is then
carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage
12 V (at 10 mA)
Maximum inrush current
30 A (300 ms)
Min. switching current
10 mA (at 12 V)
Limiting continuous current
10 A
Limiting continuous current
6 A (value applies to connections 12. If connections 12 are
bridged, the normal value applies.)
Interrupting rating (ohmic load) max.
240 W (at 24 V DC)
Interrupting rating (ohmic load) max.
58 W (at 48 V DC)
Interrupting rating (ohmic load) max.
48 W (at 60 V DC)
Interrupting rating (ohmic load) max.
50 W (at 110 V DC)
Interrupting rating (ohmic load) max.
80 W (at 220 V DC)
Interrupting rating (ohmic load) max.
2500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged
144 W (for 24 V DC. Value applies to connections 12. If
connections 12 are bridged, the normal value applies.)
Interrupting rating (ohmic load) max. bridged
1500 VA (for 250 V AC. Value applies to connections 12. If
connections 12 are bridged, the normal value applies.)
General
Operating mode
100% operating factor
Mechanical service life
3 x 10
7
 cycles
Inflammability class according to UL 94
V0
Name
Standards/regulations
Standards/regulations
IEC 60664
Standards/regulations
EN 50178
Standards/regulations
IEC 62103
Rated surge voltage / insulation
6 kV / Safe isolation, increased insulation
Pollution degree
2
Surge voltage category
III
Mounting position
Any
Assembly instructions
In rows with zero spacing
Connection data