Panasonic DSP1-5V-F PCB Mount Relay DSP15FD 데이터 시트

제품 코드
DSP15FD
다운로드
페이지 7
DSP
6
ds_61A05_en_dsp: 070313D
SAFETY STANDARDS
* Remarks: The standard certified for may differ depending on where the product was manufactured.
NOTES
Item
UL/C-UL (Recognized)
CSA (Certified)
TÜV (Certified)
File No.
Contact rating
File No.
Contact rating
File No.
Rating
1 Form A
E43028
8A 250V AC
1
/
6
HP 125, 250V AC
5A 30V DC
LR26550 
etc.
8A 250V AC
1
/
6
HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
8A 250V AC (cos
=1.0)
5A 250V AC (cos
=0.4)
5A 30V DC
1 Form A
1 Form B
E43028
5A 250V AC
1
/
6
HP 125, 250V AC
5A 30V DC
LR26550 
etc.
5A 250V AC
1
/
6
HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
5A 250V AC (cos
=1.0)
3A 250V AC (cos
=0.4)
5A 30V DC
2 Form A
E43028
5A 250V AC
1
/
10
HP 125, 250V AC
5A 30V DC
LR26550 
etc.
5A 250V AC
1
/
10
HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
5A 250V AC (cos
=1.0)
3A 250V AC (cos
=0.4)
5A 30V DC
3. 2 Form A type
External dimensions
General tolerance: 
0.3 
.012
PC board pattern (Bottom view)
0.8
0.8
0.3
10.0 10.5
3.5
1.0
20.2
7.62
7.2
1.21
10.16
0.8
0.8
0.3
10.0 10.5
3.5
1.0
1.0
20.2
7.62
7.62
7.2
1.21
2.54
0.3
11.0
7.62
.031
.031
.100
.031
.012
.394 .413
.138
.039
.795
.300
.283
.048
.400
.031
.012
.394 .413
.138
.039
.039
.795
.300
.300
.283
.048
.012
.433
.300
Single side stable
2 coil latching
Tolerance: 
0.1 
.004
Schematic (Bottom view)
6-1.2 dia.
2.54
×3
2.54
×3
2.54
×4
6-.047 dia.
.100
×3
.100
×4
.100
×3
8-1.2 dia.
2.54
×3 2.54×3
2.54
×3
2.54
8-.047 dia.
.100
×3
.100
×3 .100×3
.100
Single side stable
(Deenergized condition)
2 coil latching
(Reset condition)
8
1
+
-
16
5
9
12
1
+
-
16
2
+
-
15
8
5
9
12
1. Soldering should be done under the 
following conditions:
250
C 
482
F
 within 10 s
300
C 
572
F
 within 5 s
350
C 
662
F
 within 3 s
2. Cleaning
For automatic cleaning, the boiling 
method is recommended. Avoid 
ultrasonic cleaning which subjects the 
relays to high frequency vibrations, which 
may cause the contacts to stick.
It is recommended that a fluorinated 
hydrocarbon or other alcoholic solvents 
be used.
3. External magnetic field
Since DY relays are highly sensitive 
polarized relays, their characteristics will 
be affected by a strong external magnetic 
field. Avoid using the relay under that 
condition.
4. Coil operating power
Pure DC current should be applied to the 
coil. The wave form should be 
rectangular. If it includes ripple, the ripple 
factor should be less than 5%.
However, check it with the actual circuit 
since the characteristics may be slightly 
different.
5. When using, please be aware that 
the a contact and b contact sides of 1 
Form A and 1 Form B types may go on 
simultaneously at operate time and 
release time.