7
 
 
----------------- Operations 
 
Front Panel 
On-line LED & Selected LED 
When the LED turns green, the connected computer is powered-on.  
When a computer is selected, its corresponding red LED illuminates. 
 
Push-buttons 
Each computer has a button associated with it on the front panel for 
selection.   
 
K/M RESET 
K/M RESET
 solves most problems developed by keyboard, mouse, 
device replacement or change of configuration.  Press down both the 
front-panel number 1 and 2 push buttons for 2 seconds to re-configure 
the whole system without turning either the USB KVM switch or any 
computer off. 
 
AUTO SCAN 
Auto Scan automatically scans through computers one by one in a 
fixed interval (see Scan Time below). To initiate Auto Scanning, for 
NS431H, you can press down both the front-panel number 3 and 4 
buttons for 2 seconds. For NS831DH and NS1631DH, press 7 and 8 
instead.   
 
Note: For NS431H model only: computers using USB keyboard and 
mouse are not immediately operable when selected during Auto 
Scan. Wait for about three seconds after switching to a USB 
computer, and then use the keyboard and mouse.
 
 
 
 
 
 
 
 
 
 
 
 
 
8
 
OSD (On-Screen-Display) Operation 
OSD models only
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 6: OSD screen illustration 
 
By hitting the left   Ctrl   key twice within two seconds, you may see 
the 'Hotkey Menu' if it is enabled (an OSD option). Or, by hitting the 
left   Ctrl  key three times within two seconds, you will see a 'KVM 
MENU
' screen showing a list of the computers with corresponding port 
numbers, names and status, see Figure 6. 
 
The port number of the currently selected computer is displayed in red, 
same as the front indicator, at the right corner of the OSD menu.