Posco Indoor panel mounted lamp 72163 POL1 White 72163 POL1 사용자 설명서
제품 코드
72163 POL1
Reg. No. :PLSS-12-
Installation Manual For General Lighting 4/5
_________________________________________________________________________________________________________________________
____________________________________________________________________________________________________________________
Copyright
2013.POSCO LED CO., LTD.
www.poscoled.com
INSTALL LUMINAIRE
1. Choose the location for your new fitting
2. Make recessed opening
hole in your ceiling
(Refer to table 1)
[Figure 1]
Ordering No
Luminaire
Size
Cut out
Diameter [mm]
Remark
NDL42xx7xxB00
4 inch
100-105
NDL52xx7xxB00
5 inch
125-135
NDL62xx7xxB00
6 inch
155-165
NDL82xx7xxB00
8 inch
205-225
[Table 1] Opening diameter by model
3. Connection of AC power according to [Figure 2] & [Table2]
[Figure 2] Connection Diagram
※ On top of luminaire located terminal block is allows in and out power
line looping
Connector
Symbol
Description
Wire color
Remark
L
Live
Brown
N
Neutral
Blue
Ground
(Earth)
Yellow/Green
[Table 2] Terminal wire color assign
4. After connection of AC wire, Install the unit onto the ceiling
holding the spring clips upwards offer the body of the fitting into
the hole and allow the springs to pull the fitting up to the ceiling
(Refer to figure 3,4)
[Figure 3]
[Figure 4]
CAUTION
●
Observe the position of the spring
when disassembling, note risk of
trapping
5. Inspect the unit to ensure installation.(Refer to figure 5)
6. Switch on(or Breaker) main power to light up the unit.
CAUTION
●
Do not put any heating device under this unit, such as a
stove,oven or microwave oven.
●
Keep a distance of 50cm between unit to both wall at side
thermal insulation material and to the roof (Refer to figure 5)
●
The minimum distance between the unit and lluminated
surface should be 20cm
[Figure 5] Minimum distance for Safty
Press to release wire
Inlet wire
Outlet wire
Min.50 cm
Min.50 cm
Min.50 cm
※
Ceiling Board thickness : 3 ~25mm