at start-up. This code must be received and stored by the Weather Station in the first 3 
minutes of power being supplied to the transmitter. 
 
BATTERY CHANGE: 
It is recommended to replace the batteries in all units on an annual basis to ensure optimum 
accuracy of these units. 
 
Please participate in the preservation of the environment. Return used 
batteries to an authorized depot. 
 
 
 
 
SETTING UP 
 
WHEN ONE TRANSMITTER IS USED 
1. 
First, insert the batteries in the transmitter (see “How to install and replace batteries 
in the Termo-hygro outdoor transmitter” above). 
2. 
Within 2 minutes of powering up the transmitter, insert the batteries in the Temperature 
Station (see “How to install and replace batteries in the Weather Station” above). 
Once the batteries are in place, all segments of the LCD will light up briefly and a short 
signal tone will sound. Following the indoor temperature/humidity and the time as 0:00 
will be displayed. If these information are not displayed on the LCD after 60 seconds, 
remove the batteries and wait for at least 60 seconds before reinserting them. Once 
the indoor data is displayed user may proceed to the next step. 
3. 
After the batteries are inserted, the Weather station will start receiving data signal from 
the transmitter. The outdoor temperature and humidity data should then be displayed 
on the Weather station. If this does not happen after 2 minutes, the batteries will need 
to be removed from both units and reset from step 1. 
4. 
In order to ensure sufficient 868 MHz transmission however, the distance between the 
Weather Station and the transmitter should not be more than 100 meters (see notes on 
“Positioning” and “868 MHz Reception”). 
 
Note: 
In the event of changing batteries of the units, ensure the batteries do not spring free from 
the contacts. Always wait at least 1 minute after removing the batteries before reinserting, 
otherwise start up and transmission problems may occur. 
 
WHEN MORE THAN ONE TRANSMITTER IS USED 
1. 
User shall remove all the batteries from the Weather Station and transmitters, and wait 
60 seconds. 
2. 
Insert the batteries in the first transmitter. 
3. 
Within 2 minutes of powering up the first transmitter, insert the batteries in the Weather 
Station. Once the batteries are in place, all segments of the LCD will light up briefly 
and a short signal tine will sound. Following the indoor temperature/humidity and the 
time as 0:00 will be displayed. If these information are not displayed on the LCD after 
60 seconds, remove the batteries from both units and wait for at least 60 seconds 
before reinserting them. 
4. 
The outdoor temperature and humidity data from the first transmitter (channel 1) 
should then be displayed on the Weather Station. Also, the signal reception icon will be 
displayed. If this does not happen after 2 minutes, the batteries will need to be 
removed from both units and reset from step 1. 
5. 
Insert the batteries in the second transmitter as soon as the outdoor temperature and 
humidity readings from the first transmitter are displayed on the Weather Station. 
Note :
  User shall insert the batteries into the second transmitter within 45 seconds 
after the Weather Station displays the information of the first transmitter. 
6. 
The outdoor temperature and humidity from the second transmitter and the "channel 2"