Insys Modem 56k small INT USB 1.0 11-02-01-01-44.001 사용자 설명서

제품 코드
11-02-01-01-44.001
다운로드
페이지 97
Functions 
INSYS Modem 56k small INT 2.0/USB 1.0  
22 
June 06
 
 
5.2.2  Data Buffer for Serial Data Transmission 
The modem has a fast send and receive cache (so-called buffer) to 
adjust the modem to the operating speed of the application. It is, 
however, possible to deactivate this data buffering and switch to 
bit direct mode. 
When working with buffers, handshake is recommended to 
avoid transmission errors. 
5.2.3  Bit direct mode 
 
Only for special, non-standard data formats. 
 
 
In bit direct mode, the modem has no influence on the trans-
mission format. Data is transmitted without buffering. 
Data compression or error correction will not work in bit direct 
mode. Only the abort sequence - default +++ - is utilized by the 
modem. 
5.2.4  Hardware Data Flow Control with RTS/CTS 
Hardware Data Flow Control with the Modem (CTS): 
 
Modem 
 
RS232 Cable 
 
CTS Line 
Application 
(E.g.: PC or con-
trol) 
When the input buffer of the modem exceeds a certain fill state, 
the modem will set the CTS line to OFF. This indicates to the ap-
plication not to send any data. 
After the modem has operated the input buffer so far that the 
XON buffer falls below a certain fill state, it switches the CTS line 
back ON and reports to the application that it is ready to receive 
data again.  
AT\N1 
AT&K3
AT&R1