MATERIAL SAFETY DATA SHEET    Carbon Loaded Web         
  02/28/11
 
   
   
_________________________________________________________________________________________________ 
                                                                                                                                                                                                                                                                                                                           
Page    3    of        7   
 
  Autoignition temperature
 
  >=250 ºC
 
  Flash Point
 
  >=93 ºC [Test Method: Closed Cup]
 
  Flammable Limits(LEL)
 
  Not Applicable
 
  Flammable Limits(UEL)
 
  Not Applicable
 
 
5.2      EXTINGUISHING MEDIA
 
Use fire extinguishers with class B extinguishing agents (e.g., dry chemical, carbon dioxide).     
 
 
5.3      PROTECTION OF FIRE FIGHTERS
 
 
Special Fire Fighting Procedures:    
Wear full protective equipment (Bunker Gear) and a self-contained breathing apparatus (SCBA).     
 
 
Unusual Fire and Explosion Hazards:    No unusual fire or explosion hazards are anticipated.     
 
 
  SECTION 6: ACCIDENTAL RELEASE MEASURES
 
 
6.1. Personal precautions, protective equipment and emergency procedures 
Not applicable. 
 
6.2. Environmental precautions 
Not applicable. 
 
Clean-up methods 
Not applicable. 
 
 
 
  SECTION 7: HANDLING AND STORAGE
 
 
7.1      HANDLING
 
Avoid breathing of dust created by cutting, sanding, grinding or machining.    This product is considered to be an article which does 
not release or otherwise result in exposure to a hazardous chemical under normal use conditions.    Avoid eye contact with dust or 
airborne particles.     
 
7.2      STORAGE
 
Store away from acids.    Store away from heat.    Store out of direct sunlight.    Not applicable.     
 
  SECTION 8:    EXPOSURE CONTROLS/PERSONAL PROTECTION
 
 
8.1      ENGINEERING CONTROLS
 
Provide local exhaust ventilation at transfer points.    Not applicable.    Provide appropriate local exhaust for cutting, grinding, sanding 
or machining.    Provide ventilation adequate to control dust concentrations below recommended exposure limits and/or control dust.   
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below Occupational Exposure Limits 
and/or control dust, fume, or airborne particles.    If ventilation is not adequate, use respiratory protection equipment.   
 
 
8.2      PERSONAL PROTECTIVE EQUIPMENT (PPE)
 
 
8.2.1      Eye/Face Protection
 
Not applicable.