4. Performance Testing
4.1. TEST CONDITIONS
4.1. TEST CONDITIONS
4.1.1 The battery to be tested is the product within one month after being received by customer.
4.1.2 Ambient conditions:
Temperature +20 ±5
℃
℃
Humidity +65%±20%
4.2 Testing Tools
4.2.1 Voltage meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V.
4.2.2 Current meter:
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than
0.01Ω/V(including wires).
0.01Ω/V(including wires).
4-2.3. Micrometer caliper:
With precision of 0.02mm.
4-2.4. Internal impedance meter:
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4.
4-2.5: Impedance loaded meter:
Value of impedance is with +5% error allowed (including external wires).
4.2.6 Incubators Accuracy ±2℃
4.3 Test methods and benchmarks
Item Test
Method Benchmark
1.Appearance:
eyeballing
batteries shall be free from
any stains; scratches or
deformations, which may
reduce the commercial value
when visually inspected
deformations, which may
reduce the commercial value
when visually inspected
2.Size:
caliper measurement。
The size shall comply with the
specified size as the attached
drawing
drawing
3.Insulate
impedance
measured with a Megger overpack
and battery electrode between the
degree of insulation。
degree of insulation。
outer sleeve shall exceed 10
MΩ。
4.Weight
using disk-scale measurement。
approximate 12.0 g。
5.Charge
Voltage
Following a period of discharge at
0.2CmA down to a terminal voltage
of 1.0V, standard charge, the cell or
battery shall be checked at 5 minutes
before finish charging。
of 1.0V, standard charge, the cell or
battery shall be checked at 5 minutes
before finish charging。
The voltage shall be less than
1.6 V。
6.Open circuit
voltage: (O.C.V.)
voltage: (O.C.V.)
Following a standard charge period,
the open circuit voltage of the cell or
battery shall be checked within 1
hour.。
battery shall be checked within 1
hour.。
The O.C.V. shall exceed 1.25
V per cell.。
7.Closed
circuit voltage:
circuit voltage:
Following a standard charge period,
the closed circuit voltage of the cell
The C.C.V. shall exceed 1.2
V per cell 。