Texas Instruments MSP 430 USB Wireless Development Tool eZ430-RF2500 eZ430-RF2500 사용자 설명서

제품 코드
eZ430-RF2500
다운로드
페이지 24
www.ti.com
Frequently Asked Questions (FAQ)
8. When trying to compiler the Sensor Monitor Demo project in IAR, I receive the following error:
Error[e117]: Incompatible runtime models. Module ISR specifies that '__rt_version' must be '3', but
module LHAL_GDOxHandlers has the value '2'
Please use the latest version of the demo source code off the web (
and use IAR KickStart 4.x.
Early versions of the demo code included a precompiled version of the SimpliciTI library for IAR 3.x.
IAR 4.x changes the calling conventions, which returns Error[e117] when trying to build libraries for an
older version of the compiler.
9. What kind of range should I expect to get with the eZ430-RF2500?
Based on practical rage testing with one node connected to a PC and the other node connected to the
battery board, we have measured indoor line-of-sight range of more than 50 meters. This range can be
significantly affected by the orientation of the boards and the environment. Note that the
eZ430-RF2500 target board was designed to optimize for factor and does not focus on maximizing RF
range. Please visit the TI website for additional reference designs and antenna options.
10. Why is my battery board different than in the documentation?
Since introduction, the eZ430RF-2500 battery board was slightly modified. The connections and
function remain the same.
SLAU227E – September 2007 – Revised April 2009
eZ430-RF2500 Development Tool
15