SNVS619B – MARCH 2010 – REVISED MAY 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ABSOLUTE MAXIMUM RATINGS
(1)
If Military/Aerospace specified devices are required, contact the Texas Instruments Semiconductor Sales Office/
Distributors for availability and specifications.
VALUE / UNIT
V
IN
, EN, DIM, ADJ to CGND
-0.3V to +7V
COMP, SS to V
EE
-0.3V to +7V
BST to HS
-0.3V to +7V
V
CC
to V
EE
-0.3V to +7.5V
CGND, DIMR, CSP, CSN, T
ON
to V
EE
-0.3V to +33V
HS to V
EE
(2)
-0.3V to +33V
LS to V
EE
-0.3V to +0.3V
HO output
HS-0.3V to BST+0.3V
DIMO to DIMR
-0.3V to +7V
LO output
LS-0.3V to V
CC
+0.3V
BST2 to V
EE
-0.3V to 40V
Maximum Junction Temperature
150°C
Power Dissipation
(3)
Internally Limited
ESD Susceptibility Human Body Model
(4)
2kV
(1)
Absolute maximum ratings are limits beyond which damage to the device may occur. Operating Ratings are conditions for which the
device is intended to be functional, but device parameter specifications may not be ensured. For ensured specifications and test
conditions, see the Electrical Characteristics.
(2)
The HS pin can go to -6V with respect to V
EE
for 30ns and +22V with respect to V
EE
for 50ns without sustaining damage.
(3)
The maximum allowable power dissipation is a function of the maximum junction temperature, T
J
(MAX), the junction-to-ambient thermal
resistance,
θ
JA
, and the ambient temperature, T
A
. The maximum allowable power dissipation at any ambient temperature is calculated
using: P
D
(MAX) = (T
J(MAX)
T
A
)/
θ
JA
. Exceeding the maximum allowable power dissipation will cause excessive die temperature, and
the regulator will go into thermal shutdown. Internal thermal shutdown circuitry protects the device from permanent damage. Thermal
shutdown engages at T
J
=175°C (typ.) and disengages at T
J
=155°C (typ).
(4)
Human Body Model, applicable std. JESD22-A114-C.
RECOMMENDED OPERATING CONDITIONS
VALUE / UNIT
Operating Junction Temperature Range
(1)
40°C to +125°C
Storage Temperature
65°C to +150°C
Input Voltage V
IN
w.r.t. CGND
3.0V to 5.8V
Input Voltage V
EE
w.r.t. CGND
-9V to -30V
ADJ Input Voltage Range to CGND
0V to V
IN
(1)
All limits specified at room temperature (standard typeface) and at temperature extremes (bold typeface). All room temperature limits are
100% production tested. All limits at temperature extremes are ensured via correlation using standard Statistical Quality Control (SQC)
methods. All limits are used to calculate Average Outgoing Quality Level (AOQL).
4
Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: