SNOSB51C – SEPTEMBER 2011 – REVISED MAY 2013
The on-time (t
ON
) and therefore the switching frequency, will vary as the V
BUCK
voltage changes with line voltage.
A good design practice is to choose a desired nominal switching frequency knowing that the switching frequency
will decrease as the line voltage drops and increase as the line voltage increases.
The off-time of the LM3448 can be programmed for switching frequencies ranging from 30 kHz to over 1MHz. A
trade-off between efficiency and solution size must be considered when designing the LM3448 application.
The maximum switching frequency attainable is limited only by the minimum on-time requirement (200 ns).
Worst case scenario for minimum on time is when V
BUCK
is at its maximum voltage (AC high line) and the LED
string voltage (V
LED
) is at its minimum value.
(14)
The maximum voltage seen by the Buck Converter is:
(15)
INDUCTOR SELECTION
The controlled off-time architecture of the LM3448 regulates the average current through the inductor (L2), and
therefore the LED string current (see
). The input voltage to the buck converter (V
BUCK
) changes with
line variations and over the course of each half-cycle of the input line voltage. The voltage across the LED string
is relatively constant, and therefore the current through R4 is constant. This current sets the off-time of the
converter and therefore the output volt-second product (V
LED
x off-time) remains constant. A constant volt-second
product makes it possible to keep the ripple through the inductor constant as the voltage at V
BUCK
varies.
Figure 34. Simplified LM3448 Buck Converter