Texas Instruments IC MCU 16B MSP430G2201IN14 PDIP-14 TID MSP430G2201IN14 데이터 시트

제품 코드
MSP430G2201IN14
다운로드
페이지 48
0
1
t d(BOR)
VCC
V(B_IT−)
Vhys(B_IT−)
V
CC(start)
MSP430G2x11
MSP430G2x01
SLAS695I – FEBRUARY 2010 – REVISED FEBRUARY 2013
POR, BOR
(1) (2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
0.7 ×
V
CC(start)
See
dV
CC
/dt
3 V/s
V
V
(B_IT-)
V
(B_IT-)
See
through
dV
CC
/dt
3 V/s
1.35
V
V
hys(B_IT-)
See
dV
CC
/dt
3 V/s
130
mV
t
d(BOR)
See
2000
µs
Pulse duration needed at RST/NMI pin to
t
(reset)
2.2 V, 3 V
2
µs
accepted reset internally
(1)
The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level V
(B_IT-)
+
V
hys(B_IT-)
is
1.8 V.
(2)
During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT-)
+ V
hys(B_IT-)
. The default DCO settings
must not be changed until V
CC
V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired operating frequency.
Figure 10. POR and BOR vs Supply Voltage
20
Copyright © 2010–2013, Texas Instruments Incorporated