Texas Instruments Battery Charger Evaluation Module BQ24087EVM BQ24087EVM 데이터 시트

제품 코드
BQ24087EVM
다운로드
페이지 11
www.ti.com
2.3
Alternative Test Procedures (Without Battery)
2.3.1
Four Quadrant Power Supply (Sinks or Source Current)
2.3.2
Large Capacitor
2.3.3
Dynamic Load Board
Test Summary
6. Once the charge terminates, J7 (TMR jumper) can be removed, putting the IC in LDO mode, and the
charger should turn on and regulate at 4.2 V or in constant current mode if the battery voltage drops
below 4.2 V. Replacing the jumper allows the IC to terminate properly.
Note:
Loads across the battery can affect termination.
7. If the battery discharges to the recharge threshold, the charger starts fast charging.
This are alternative methods of testing the EVM without a battery. These alternative test procedures
include:
Four Quadrant Power Supply (Sinks or Source Current)
Large Capacitor
Dynamic Load Board
Because of the battery detection circuit, it is difficult to test the different charge phases without a battery
(using just resistors); the algorithm sinks and sources current and applies precharge and fast-charge
current depending on the mode it is in. Applying a load that would keep the voltage at 3.5 V (3.5 V/0.7 A)
would pull the output into precharge mode and keep it there during the battery detection algorithm, which
always occurs when the output is discharged to the refresh threshold. Once in precharge mode, a load
sufficient to allow the capacitor to charge to V
(lowV)
would allow the output to jump to voltage regulation
once the 0.7-A fast charge function is activated.
A source meter that can sink current can easily be adjusted to test each mode.
To briefly see each mode on a scope, connect a 1 mF capacitor in parallel with a 20 k
Ω
resistor on the
output to observe the power up and cycling between voltage regulation and fast charge via the refresh
threshold.
The circuit is adjusted to work with the displayed parts and their inherent thresholds. The sequence of the
test procedure is important due to the active battery detection circuit, refresh feature, precharge, and
fast-charge current levels (switching the load in and out in different modes has different results). No
damage should occur, but one might get different results than anticipated if the procedure is altered.
SLUU305 – March 2008
bq24085/6/7/8 Evaluation Module
3