Advanced bqMTester Instructions
4.7.4
Locking and Unlocking the Configuration
Once all information is updated as required then click Update V, T, and I and Close. This locks the
software and enables the Start button.
To unlock the software at any time, click Configure VTI on the main screen and then click Unlock
Configuration
. A password dialog window displays. Supply the required password and click OK. The
default password is bq20z80. This password should be changed after the first use.
To change the password, click Lock Configuration. This causes a password dialog window to appear.
Enter a password and be sure to record it in a safe location for future reference. Re-enter the password to
ensure it was not misspelled. Click OK.
The software always locks when Update VTI and Close is clicked. When either Update VTI and Close or
Lock Configuration are selected, notice that the Lock Status icon changes from an open lock to a
closed lock.
4.8
Testing Modules
Once setup is completed, testing can begin. There are multiple indicators on the main screen of the
multi-station tester program and the Start button.
4.8.1
Progress Textbox
The software displays a description of the progress of the test for each station in the textbox in the upper
center of the main window (see
). Only enabled stations show in this window. Next to the
Progress textbox is a column of simulated LEDs adjacent to each station progress entry. After a test
finishes, this simulated LED turns red or green, depending on a pass or fail.
The progress steps are:
1. Verifying Device Version: Powers up the device, waits for parameters to settle, and verifies the
version of firmware to be tested.
2. Writing Data Image: Writes the Golden Image File to the data flash of the device under test
3. Calibrating: Calibrates voltage, temperature, and current
4. Verifying Calibration Limits: Verifies the calibrated gain and offset values did not go out of the
ranges selected in the Tester Setup program
5. Writing Manufacturer Data: Writes Pack Lot Code and Date, etc., as required
6. Writing Serial Number: Writes serial number
7. Pass or Error Code = XXXXX: If the test failed, then an error code is reported. The error code
displayed with a failed device in the Progress textbox will be a more detailed code than the error code
reported in the Statistics Log textbox.
4.8.2
Statistics Log Textbox
The Statistics Log textbox is located under the Progress textbox. It shows the entire past statistical test
data from all stations installed and selected. This data is also logged in a log file with the name entered in
the Log File Name field on the Global Configuration screen of the Station Setup program. When more
tests are performed than can fit in the Statistics Log textbox, a scroll bar appears on the right side of the
box and only the most recent tests will be displayed. Past data can be seen by adjusting the scroll bar.
Error codes reported here are of a more generic nature than the ones reported in the Progress testbox,
as described above. Both error codes will be logged if a log file is open.
4.8.3
Test#
Test# is the number of tests since the software was opened.
4.8.4
StationID
StationID is the name given to the station when the Station Setup software was run.
25
SLUU397A
February 2011
Revised May 2011
Advanced bqMTester
Copyright
©
2011, Texas Instruments Incorporated