Texas Instruments BQ24041 Evaluation Module: 1A Single-Input, Single-Cell Li-Ion Battery Charger BQ24041EVM BQ24041EVM 데이터 시트

제품 코드
BQ24041EVM
다운로드
페이지 10
Schematic, Physical Layouts and Bill of Materials
www.ti.com
4.3
Test Procedure Using a Single Cell Li-Ion Battery
1. Verify that the setup is correct and turn on the power supply, which was preset to 5 VDC, and 1 A for
the current-limit setting.
2. The bq24040/1 enters preconditioning mode if the battery is below the V
(LOWV)
threshold. In this mode,
the bq24040/1 pre-charges the battery with a low current programmed by the PRE-TERM resistor
(typically set to 10% of fast charge) until the battery voltage reaches the V
(LOWV)
threshold or until the
pre-charge timer expires. If the timer expires, then the charge current is terminated and the bq24040/1
enters fault mode. The CHG LED turns off when in timer fault mode. Toggling input power, toggling TS
(BAT_EN) or battery replacement resets fault mode.
3. When the battery voltage rises above the V
(LOWV)
threshold, the battery enters fast-charge constant
current mode. This EVM is programmed for 0.54 A of fast-charging current.
4. Remove the shunt from JMP3 and see the IC go into USB100 mode (charge current drops); place
shunt between ISET2 and HI and see the USB500 mode (500mA–bq24040, or 410mA–bq24041);
return shunt to ISET2-GND for programmed current.
5. Once the battery reaches the voltage regulation threshold (4.2 V), the voltage control loop takes over
and the current tapers down as the battery reaches its full capacity.
6. The battery remains at the fast-charge mode until either the charge timer expires or the charge
termination current threshold is reached.
7. When the charge terminates, the CHG LED turns off.
8. Remove JMP5 (TS) and the charger turns on. This mode is Termination and Timer Disable Mode
(TTDM). This allows continuous power applied from the input to the output, regulated to 4.2V with a
maximum current programmed by the ISET resistor (can be restricted further if in USB mode). The
system can operate without a battery in this mode as long as the system does not exceed the supplied
input current.
9. If the battery discharges to the recharge threshold, the charger starts fast charging, but the CHG LED
will not come on for the subsequent charges. Cycling the input power, replacing the battery, or toggling
the TS pin low starts a new charge with the CHG LED on.
NOTE:
Loads across the battery can affect termination. The pre-term pin can be adjusted to offset
the system current. See data sheet for more details.
4.4
Alternate Test Methods
A 4-quadrant power supply that can source and sink current can be used in place of the battery pack to
evaluate the charger. It allows each transfer between pre-charge, constant-current and constant voltage
fast charge. Keep leads short to avoid adding too much inductance which may cause an interaction
between the power supply and charger. A large capacitor across the output helps cancel the inductance if
long leads are necessary.
5
Schematic, Physical Layouts and Bill of Materials
4
0.8-A Single-Input, Single-Cell Li-Ion Battery Charger
SLUU377 – September 2009
Copyright © 2009, Texas Instruments Incorporated