Texas Instruments DAC3162 Evaluation Module DAC3162EVM DAC3162EVM 데이터 시트

제품 코드
DAC3162EVM
다운로드
페이지 9
Testing and Configuration
www.ti.com
2.3
TSW3100 Quick-Start Operation
Refer to the
for a more detailed discussion of how to set up and operate the
TSW3100. This user guide presumes that the TSW3100 software is installed and functioning properly.
CommsSignalPattern Setup from Default Configuration (WCDMA):
Step 1.
Change the interpolation value to DAC Clock Rate / 3.84 (that is, 491.52/3.84 = 128).
Step 2.
Enter the desired offset frequency (for example, 30 MHz) for each desired carrier.
Step 3.
Select the LVDS Output button.
Step 4.
Select the Offset Binary option.
Step 5.
Check the LOAD and Run box.
Step 6.
Press the green Create button.
shows a screenshot of the properly configured TSW3100 software interface.
Figure 3. TSW3100 CommsSignalPattern (WCDMA) Programming GUI
4
DAC31x2EVM
SBOU096A – November 2010 – Revised January 2011
© 2010–2011, Texas Instruments Incorporated